SLOS743L – AUGUST 2011 – REVISED MARCH 2017
Product Folder Links:
Detailed Description
Copyright © 2011–2017, Texas Instruments Incorporated
6.15.3.5 FIFO Control Registers
describes the FIFO Status register.
6.15.3.5.1 FIFO Status Register (0x1C)
Table 6-56. FIFO Status Register (0x1C)
Function:
Number of bytes available to be read from FIFO (= N number of bytes, in hexadecimal)
Bit
Name
Function
Description
B7
Foverflow
FIFO overflow error
Bit is set when FIFO has more than 127 bytes presented to it
B6
Fb6
FIFO bytes fb[6]
Bits B0:B6 indicate how many bytes are in the FIFO to be read out (= N
number of bytes, in hex)
B5
Fb5
FIFO bytes fb[5]
B4
Fb4
FIFO bytes fb[4]
B3
Fb3
FIFO bytes fb[3]
B2
Fb2
FIFO bytes fb[2]
B1
Fb1
FIFO bytes fb[1]
B0
Fb0
FIFO bytes fb[0]