6.15.3.5.2 TX Length Byte1 Register (0x1D), TX Length Byte2 Register (0x1E)
describes the TX Length Byte1 register.
describes the TX Length Byte2 register.
Table 6-57. TX Length Byte1 Register (0x1D)
Function:
High 2 nibbles of complete, intended bytes to be transferred through FIFO
Register default is set to
0x00 at POR and EN = 0. It is also automatically reset at TX EOF
Bit
Name
Function
Description
B7
Txl11
Number of complete byte
bn[11]
High nibble of complete, intended bytes to be transmitted
B6
Txl10
Number of complete byte
bn[10]
B5
Txl9
Number of complete byte
bn[9]
B4
Txl8
Number of complete byte
bn[8]
B3
Txl7
Number of complete byte
bn[7]
Middle nibble of complete, intended bytes to be transmitted
B2
Txl6
Number of complete byte
bn[6]
B1
Txl5
Number of complete byte
bn[5]
B0
Txl4
Number of complete byte
bn[4]
Table 6-58. TX Length Byte2 Register (0x1E)
Function:
Low nibbles of complete bytes to be transferred through FIFO; Information about a broken byte and number of bits to be
transferred from it
Default:
0x00 at POR and EN = 0. It is also automatically reset at TX EOF
Bit
Name
Function
Description
B7
Txl3
Number of complete byte
bn[3]
Low nibble of complete, intended bytes to be transmitted
B6
Txl2
Number of complete byte
bn[2]
B5
Txl1
Number of complete byte
bn[1]
B4
Txl0
Number of complete byte
bn[0]
B3
Bb2
Broken byte number of bits
bb[2]
Number of bits in the last broken byte to be transmitted.
Valid only when broken byte flag is set.
B2
Bb1
Broken byte number of bits
bb[1]
B1
Bb0
Broken byte number of bits
bb[0]
B0
Bbf
Broken byte flag
B0 = 1 indicates that last byte is not complete 8 bits wide.