38
SLOS758G – DECEMBER 2011 – REVISED MARCH 2020
Product Folder Links:
Detailed Description
Copyright © 2011–2020, Texas Instruments Incorporated
Figure 6-23. Receive Data Bits and Framing Level (ISO/IEC 14443 A)
Step 7:
Exit direct mode 0
When an EOF is received, data transmission is over, and direct mode 0 can be terminated by sending a
Stop condition (the SS signal goes high). The TRF7963A returns to ISO Mode (normal mode).