6.13 Device Descriptors (TLV)
summarizes the Device IDs of the MSP432P401xx MCUs.
lists the contents of the
device descriptor tag-length-value (TLV) structure for the MSP432P401xx MCUs.
Table 6-85. Device IDs
DEVICE
DEVICE ID
MSP432P401RIPZ
0000A000h
MSP432P401MIPZ
0000A001h
MSP432P401RIZXH
0000A002h
MSP432P401MIZXH
0000A003h
MSP432P401RIRGC
0000A004h
MSP432P401MIRGC
0000A005h
(1)
per unit = content can differ from device to device
Table 6-86. Device Descriptor Table
(1)
DESCRIPTION
ADDRESS
VALUE
TLV checksum
00201000h
per unit
Info Block
Device Info Tag
00201004h
0000000Bh
Device Info Length
00201008h
00000004h
Device ID
0020100Ch
See
Hardware Revision
00201010h
per unit
Boot-Code Revision
00201014h
per unit
ROM Driver Library Revision
00201018h
per unit
Die Record
Die Record Tag
0020101Ch
0000000Ch
Die Record Length
00201020h
00000008h
Die X Position
00201024h
per unit
Die Y Position
00201028h
per unit
Wafer ID
0020102Ch
per unit
Lot ID
00201030h
per unit
Reserved
00201034h
per unit
Reserved
00201038h
per unit
Reserved
0020103Ch
per unit
Test Results
00201040h
per unit
Clock System
Calibration
Clock System Calibration Tag
00201044h
00000003h
Clock System Calibration Length
00201048h
00000010h
DCO IR mode: Frequency calibration for DCORSEL 0 to 4
0020104Ch
per unit
DCO IR mode: Frequency calibration for DCORSEL 5
00201050h
per unit
Reserved
00201054h
not defined
Reserved
00201058h
not defined
Reserved
0020105Ch
not defined
Reserved
00201060h
not defined
DCO IR Mode: DCO Constant (K) for DCORSEL 0 to 4
00201064h
per unit
DCO IR Mode: DCO Constant (K) for DCORSEL 5
00201068h
per unit
DCO ER Mode: Frequency calibration for DCORSEL 0 to 4
0020106Ch
per unit
DCO ER Mode: Frequency calibration for DCORSEL 5
00201070h
per unit
Reserved
00201074h
not defined
Reserved
00201078h
not defined
Reserved
0020107Ch
not defined
Reserved
00201080h
not defined
DCO ER Mode: DCO Constant (K) for DCORSEL 0 to 4
00201084h
per unit
DCO ER Mode: DCO Constant (K) for DCORSEL 5
00201088h
per unit