Time
DATA
Threshold = 128+Hysteresis
Button 0
Button 1
Common-mode change
to both Buttons 0 and 1.
Intentional Press
of Button 1
OUTPUT
without
Anti-common
(High = Button
Press Detected)
Button 0
Button 1
OUTPUT
with
Anti-common
(High = Button
Press Detected)
Button 0
Button 1
Time
Time
Figure 8-10. Illustration of the Anti-Common Feature
8.1.10.2 Resolving Simultaneous Button Presses (Max-Win)
This algorithm enables the system to select the button pressed with maximum force when multiple buttons are
pressed at the same time. This could happen when two buttons are physically very close to each other, and
pressing one causes a residual reaction on the other. Buttons can be individually enabled to join the “max-win”
group by configuring
Register BTPAUSE_MAXWIN (Address 0x16)
.
Time
DATA
Threshold = 128+Hysteresis
Button 0
Button 1
Intentional Press of Button 0
with coupled response of
Button 1
Intentional Press of
Button 1
OUTPUT
without
Max-Win
(High = Button
Press Detected)
Button 0
Button 1
OUTPUT
with
Max-Win
(High = Button
Press Detected)
Button 0
Button 1
Time
Time
Figure 8-11. Illustration of the Max-Win Feature
SNOSDD0 – DECEMBER 2021
Copyright © 2021 Texas Instruments Incorporated
45