![Texas Instruments BQ76942 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/texas-instruments/bq76942/bq76942_manual_1095628013.webp)
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
C
BREG
External capacitor BREG to VSS
150
pF
(1)
Supported output current is limited for V
STACK
< 5.5 V. V
REGIN
limited to 2.5 V below V
BAT
.
(2)
Capacitance should be above 7 nF after consideration for aging and derating.
(3)
Specified by design
7.12 REG1 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
REG1_1.8
Regulator voltage (nominal 1.8V setting)
V
REGIN
≥ 3.0 V, I
REG1
= 0 mA to 45 mA
1.6
1.84
2
V
V
REG1_2.5
Regulator voltage (nominal 2.5V setting)
V
REGIN
≥ 3.5 V, I
REG1
= 0 mA to 45 mA
2.25
2.55
2.75
V
V
REG1_3.0
Regulator voltage (nominal 3.0V setting)
V
REGIN
≥ 3.8 V, I
REG1
= 0 mA to 45 mA
2.7
3.05
3.3
V
V
REG1_3.3
Regulator voltage (nominal 3.3V setting)
V
REGIN
≥ 4.1 V, I
REG1
= 0 mA to 45 mA
3.0
3.36
3.6
V
V
REG1_5.0
Regulator voltage (nominal 5.0V setting)
V
REGIN
≥ 5.0 V, I
REG1
= 0 mA to 45 mA
4.5
5.19
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG1
vs (V
REG1
at 25°C, I
REG1
=
20 mA, V
REGIN
= 5.5 V, V
REG1
set to
nominal 3.3 V setting)
±0.25
%
ΔV
O(LINE)
Line regulation
ΔV
REG1
vs (V
REG1
at 25°C, V
REGIN
=
5.5 V, I
REG1
= 20 mA), as V
REGIN
varies
from 5 V to 6 V, V
REG1
set to nominal
3.3 V setting
–1
1
%
I
SC
Regulator short-circuit current limit
V
REG1
= 0 V
47
80
mA
C
EXT
External capacitor REG1 to VSS
1
µF
(1)
Specified by design
7.13 REG2 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
REG2_1.8
Regulator voltage (nominal 1.8V setting)
V
REGIN
≥ 3.0 V, I
REG2
= 0 mA to 45 mA
1.6
1.84
2
V
V
REG2_2.5
Regulator voltage (nominal 2.5V setting)
V
REGIN
≥ 3.5 V, I
REG2
= 0 mA to 45 mA
2.25
2.55
2.75
V
V
REG2_3.0
Regulator voltage (nominal 3.0V setting)
V
REGIN
≥ 3.8 V, I
REG2
= 0 mA to 45 mA
2.7
3.06
3.3
V
V
REG2_3.3
Regulator voltage (nominal 3.3V setting)
V
REGIN
≥ 4.1 V, I
REG2
= 0 mA to 45 mA
3.0
3.38
3.6
V
V
REG2_5.0
Regulator voltage (nominal 5.0V setting)
V
REGIN
≥ 5.0 V, I
REG2
= 0 mA to 45 mA
4.5
5.23
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG2
vs (V
REG2
at 25°C, I
REG2
=
20 mA, V
REGIN
= 5.5 V, V
REG2
set to
nominal 3.3 V setting)
±0.25
%
ΔV
O(LINE)
Line regulation
ΔV
REG2
vs (V
REG2
at 25°C, V
REGIN
=
5.5 V, I
REG2
= 20 mA), as V
REGIN
varies
from 5 V to 6 V, V
REG2
set to nominal
3.3 V setting
–1
1
%
I
SC
Regulator short-circuit current limit
V
REG2
= 0 V
47
80
mA
C
EXT
External capacitor REG2 to VSS
1
µF
(1)
Specified by design
SLUSE14B – DECEMBER 2020 – REVISED DECEMBER 2021
Copyright © 2021 Texas Instruments Incorporated
13
Product Folder Links:
Содержание BQ76942