Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
I
(PULLDOWN)
Current sink capability, PCHG and
PDSG
PCHG and PDSG enabled, V
BAT
= 37.0 V
30
µA
7.9 FUSE Pin Functionality
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
(OH)
Output voltage high (when driving fuse)
V
BAT
≥ 8 V, C
L
= 1 nF, 5 kΩ load.
6
7
9
V
V
(OH)
Output voltage high (when driving fuse)
4.7 V ≤ V
BAT
< 8 V, C
L
= 1 nF, 5 kΩ load.
V
BAT
–
1.75
V
V
(IH)
High-level input (for fuse detection)
Current into device pin must be limited to
maximum 2 mA
2
12
V
V
(IL)
Low-level input (for fuse detection)
0.7
V
t
(RISE)
Output rise time (when driving fuse)
V
BAT
≥ 8 V, C
L
= 1 nF, R
SERIES
= 100
Ω, V
(OH)
= 10% to 90% of final settled
voltage
0.5
µs
7.10 REG18 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
C
REG18
External capacitor, REG18 to VSS
1.8
2.2
22
µF
V
REG18
Regulator voltage
1.6
1.8
2
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG18
vs (V
REG18
at 25°C), I
REG18
= 1
mA, V
BAT
= 37.0 V
±0.15
%
ΔV
O(LINE)
Line regulation
ΔV
REG18
vs (V
REG18
at 25°C, V
BAT
= 37.0
V), I
REG18
= 1 mA, as V
BAT
varies across
specified range
–0.6
0.5
%
ΔV
O(LOAD)
Load regulation
ΔV
REG18
vs (V
REG18
, V
BAT
= 37.0 V),
I
REG18
= 0 mA to 1 mA, at 25°C
–1.5
1.5
%
I
SC
Regulator short-circuit current limit
V
REG18
= 0 V
3
14
mA
(1)
Specified by design
7.11 REG0 Pre-regulator
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
BREG_HDRM
Pre-regulator control voltage
headroom ( min(V
BAT
- V
BREG
) )
V
BAT
≥ 4.7 V
1.5
1.9
V
V
REGIN_INT
Pre-regulator voltage, when
generated using BREG
V
BAT
> 8 V, although specific requirement
depends on external device selected
5
5.5
5.8
V
V
REGIN_EXT
Pre-regulator voltage when using
externally supplied REGIN
See requirements based on settings of
REG1 and REG2
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REGIN
vs V
REGIN
at 25°C, I
REGIN
= 50
mA, V
BAT
> 8 V
±0.05
%
I
Max
Maximum current driven out from
BREG
Under short circuit conditions (V
REGIN
= 0
V)
2.5
3.33
mA
C
EXT
External capacitor REGIN to VSS
15
22
27
nF
SLUSE14B – DECEMBER 2020 – REVISED DECEMBER 2021
12
Copyright © 2021 Texas Instruments Incorporated
Содержание BQ76942
Страница 84: ......