CS
Sample
CHy
SCLK
Sample
CH2
Sample
CH5
Data CHx
Data CHy
Data CH2
SDO
t
CYCLE
AUTO-1 Start
SDI
Scan channels CH2 , CH5 and CH6
Data CH5
Sample
CH6
Data CH6
AUTO-1
AUTO-1
AUTO1
AUTO-1
Frame N
Frame (N + 1)
Frame (N + 2)
Frame (N + 3)
35
ADS7950, ADS7951, ADS7952, ADS7953, ADS7954, ADS7955
ADS7956, ADS7957, ADS7958, ADS7959, ADS7960, ADS7961
SLAS605C – JUNE 2008 – REVISED JULY 2018
Product Folder Links:
ADS7950 ADS7951 ADS7952 ADS7953 ADS7954 ADS7955 ADS7956 ADS7957 ADS7958
Copyright © 2008–2018, Texas Instruments Incorporated
Consider a case where Auto-1 mode is selected to scan channels 2 (CH2), 5 (CH5), and 6 (CH6) as represented
in
. The program register for Auto-1 mode must be programmed as described in
before
entering into this auto sequencing mode. The device enters into Auto-1 mode on receiving the Auto-1 mode
command in the Nth frame. This step causes the device to find the first enabled channel in ascending order and
switch the MUX for CH2 in the (N+1)th frame. In the (N+2)th frame, the ADC samples the signal on CH2, shifts
out the conversion results, and the MUX also internally switches to CH5. In the (N+3)th frame, the ADC samples
and shifts out the conversion result for CH5 and the MUX also internally switches to CH6. This process repeats
until the last enabled channel is reached, in which case the process loops back to the first enabled channel.
Entering Auto-1 mode from any other mode also causes the device to restart from the first enabled channel.
However, modifying the contents of the Auto-1 mode program register while operating in Auto-1 mode causes
the device to scan for the next enabled channel.