Device power up or reset
Device operation in manual mode, Channel 0;
SDO Invalid in first frame
CS
First frame
CS
CS
CS
CS
Operation in manual mode
CS
CS
CS
Auto 1 register program (note 1)
Auto 2 register program (note 1)
Alarm register program (note 1)
GPIO register program (note 1)
Operation in Auto 1 mode
Operation in Auto 2 mode
31
ADS7950, ADS7951, ADS7952, ADS7953, ADS7954, ADS7955
ADS7956, ADS7957, ADS7958, ADS7959, ADS7960, ADS7961
SLAS605C – JUNE 2008 – REVISED JULY 2018
Product Folder Links:
ADS7950 ADS7951 ADS7952 ADS7953 ADS7954 ADS7955 ADS7956 ADS7957 ADS7958
Copyright © 2008–2018, Texas Instruments Incorporated
Device Functional Modes (continued)
(1)
The device continues its operation in manual mode channel 0 throughout the programming sequence and outputs
valid conversion results. It is possible to change channel, range, GPIO by inserting extra frames in between two
programming blocks. It is also possible to bypass any programming block if the user does not intend to use that
feature.
(2)
It is possible to reprogram the device at any time during operation, regardless of what mode the device is in. During
programming the device continues its operation in whatever mode it is in and outputs valid data.
Figure 49. Device Power-Up Sequence
8.4.4 Operating in Manual Mode
The flowchart in
illustrates the steps involved in operating in manual channel sequencing mode.
lists the mode control register settings for manual mode. There are no program registers in manual