Parameter
Explanation and setting options
Hi�T
max� value of the temperature measured in the process
Lo�P
min� value of the pressure measured in the process
Hi�P
max� value of the pressure measured in the process
7.6.4 Submenu DIS
Parameter
Explanation and setting options
diS�L
standard process value display
L1
= current process value for volumetric flow
L2�Temp = current process value for flow and temperature
L2�Pres = current process value for volumetric flow and pressure
L2�Totl = current process value for volumetric flow and totaliser
L3�TP = current process value for volumetric flow and temperature and
pressure
L4
= current process value for volumetric flow and temperature and
pressure and current totaliser value
diS�U
update rate of display
d1 = high
d2 = medium
d3 = low
diS�R
display rotation: 0°, 90°, 180°, 270°
diS�B
display brightness: 25 %, 50 %, 75 %, 100 %, OFF (measured value
display in the RUN mode switched off)
7.6.5 Submenu COLR
Parameter
Explanation and setting options
coL�F
colour of the characters in the display for the flow rate value
cFH�F
upper limit of the colour change for flow rate measurement
cFL�F
lower limit of the colour change for flow rate measurement
coL�T
colour of the characters in the display for the temperature value
cFH�T
upper limit of the colour change for temperature measurement
cFL�T
lower limit of the colour change for temperature measurement
coL�P
colour of the characters in the display for the pressure value
cFH�P
upper limit of the colour change for pressure measurement
cFL�P
lower limit of the colour change for pressure measurement