4 Installation
CAUTION
If the medium temperature is above 50 °C (122 °F), parts of the
housing can increase in temperature to over 65 °C (149 °F)�
> Risk of burns�
►
Protect the housing against contact with flammable substances
and unintentional contact�
►
Apply the supplied warning label to the sensor cable�
►
Ensure that the system is free of pressure during installation�
►
The rules and regulations for the installation and operation of com-
pressed air equipment must be observed�
4.1 Installation location
►
Install the unit downstream of the cold dryer�
►
Install the unit near the load�
►
The unit can be installed downstream of a maintenance unit�
►
If oil is used for the loads: install the unit upstream of the oiler�
4.2 Installation position
4.2.1 Inlet and outlet pipe lengths
Structures in the pipe, bends, valves, reducing pieces and the like affect the
function of the unit�
►
Adhere to the distances between sensor and interference:
Interference
Distance to the sensor
changes to the pipe diameter
10 x pipe diameter
90° elbow
10 x pipe diameter
two 90° elbows, one plane
15 x pipe diameter