20
ENG
Please note that:
1. The installation site should be well-ventilated.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548 which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-
static clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets
of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or
combustible and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, it is necessary to immediately turn off the valve
of the outdoor unit and all the personnel should go out till the refrigerant leaks completely for 15 minutes. If
the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is
prohibited to weld the refrigerant pipe or conduct other operations on the user’s site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets,
kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit.
Suggested Tools
Tool
Picture
Tool
Picture
Tool
Picture
Standard
Wrench
Pipe Cutter
Vacuum Pump
Adjustable/
Crescent
Wrench
Screw drivers
(Phillips & Flat
blade)
Safety Glasses
Torque Wrench
Manifold and
Gauges
Work Gloves
Hex Keys or
Allen Wrenches
Level
Refrigerant
Scale
Drill & Drill Bits
Flaring tool
Micron Gauge
Hole Saw
Clamp on Amp
Meter