Emergency button:
Open the panel and find the emergency button on the electronic control box when the remote controller fails .
(Always press the emergency button with insulation material.)
Current status
Operation
Respond
Enter mode
Standby
Press the emergency button once
It beeps briefly once.
Cooling mode
Standby (Only for
heating pump)
Press the emergency button twice
in 3 seconds
It beeps briefly twice.
Heating mode
Running
Press the emergency button once
It keeps beeping for a
while
Off mode
control-box cover
(open the panel of indoor unit)
ON/OFF
Attempt to use the air conditioner under the temperature beyond the specified range may cause the air
conditioner protection device to start and the air conditioner may fail to operate. Therefore, try to use the air
conditioner in the following temperature conditions.
Characteristics of heating operation (applicable to Heating pump)
Preheating:
When the heating function is enabled, the indoor unit will take 2~5 minutes for preheating, after that the air
conditioner will start heating and blows warm air.
Defrosting:
During heating, when the outdoor unit frosted, the air conditioner will enable the automatic defrosting function
to improve the heating effect. During defrosting, the indoor and outdoor fans stop running. The air conditioner
will resume heating automatically after defrosting finish.
With the power supply connected, restart the air conditioner after shutdown, or switch it to other mode during
operation, and the air conditioner protection device will start. The compressor will resume operation after 3
minutes.
Temperature
Mode
Heating
Cooling
Dry
Room temperature
0
°
C~27
°
C (32
°
F~80
°
F)
17
°
C~32
°
C (63
°
F~90
°
F)
Outdoor temperature
-20
°
C~24
°
C
(-4
°
F~75
°
F)
15
°
C~50
°
C (59
°
F~122
°
F)