3-6
Z
®
-33/18
Part No. 1268514GT
January 2020
Section 3 • Repair Procedures
The maximum speed setting of a joystick and
toggle switch controls the maximum speed of a
machine function. Whenever a hydraulic cylinder,
drive motor or hydraulic pump is replaced, the
maximum speed setting should be adjusted to
maintain optimum performance. The maximum
speed settings can be changed to compensate
for hydraulic pump wear and to maintain peak
performance from the machine.
There are two types of max speed settings.
High flow functions
: Secondary up / down and
extend / retract.
Low flow functions
: Primary up / down and
turntable rotate.
Begin this procedure with the rotary speed control
at the platform turned fully in the clockwise
direction.
1 Turn the key switch to platform control.
2 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
3 Do not press down the foot switch.
4 Move and hold the drive enable toggle switch in
the right direction while holding the steer rocker
switch in the right direction.
PLATFORM CONTROLS
5 When the display leaves
SYSTEM READY
mode, release the drive enable toggle switch
and the steer rocker switch.
Result: The display will show
FAULTS
.
6 Momentarily activate the steer rocker switch in
the right direction until
SETTINGS
is shown on
the display.
7 Momentarily activate the drive enable toggle
switch in the right direction until
VALVE AND
PUMP SETTINGS
is shown on the display.
8 Momentarily activate the drive enable toggle
switch in the right direction until
THRESHOLD
is shown on the display.
9 Momentarily activate the steer rocker switch
in the right direction until
VALVE MAXIMUM
CURRENT
is shown on the display.
10 Momentarily activate the drive enable toggle
switch in the right direction to enter
VALVE
MAXIMUM CURRENT
calibration mode.
High flow functions:
11 Momentarily activate one of the high flow
functions full stroke.
Result: The display will show the function
direction and milliamps.
12 Press down on the foot switch and activate the
same function in the same direction again.
Result: Alarm sounds, continue to step 15.
Result: Alarm does not sound, continue to step
13.
Содержание Genie Z-33/18
Страница 6: ...vi Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Страница 12: ...xii Z 33 18 Part No 1268514GT January 2020 This page intentionally left blank ...
Страница 22: ...2 10 Z 33 18 Part No 1268514GT January 2020 Section 2 Specifications This page intentionally left blank ...
Страница 104: ...5 2 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Electrical Symbols Legends ...
Страница 105: ...January 2020 Part No 1268514GT Z 33 18 5 3 Section 5 Schematics Hydraulic Symbols Legends ...
Страница 106: ...January 2020 Section 5 Schematics 5 4 5 5 Electrical Schematic ...
Страница 108: ...January 2020 Section 5 Schematics 5 7 Electrical Schematic ...
Страница 110: ...January 2020 Section 5 Schematics 5 9 Electrical Schematic ...
Страница 112: ...January 2020 Section 5 Schematics 5 11 Electrical Schematic ...
Страница 114: ...January 2020 Section 5 Schematics 5 13 Electrical Schematic ...
Страница 115: ...5 14 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Electrical Schematic from S N Z3318M 2669 ...
Страница 116: ...5 15 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Electrical Schematic from S N Z3318M 2669 ...
Страница 117: ...5 16 Z 33 18 Part No 1268514GT January 2020 Section 5 Schematics Hydraulic Schematic ...