How to Check the Function Pump Calibration
How to Check the Function Pump
Calibration
Pump efficiency is calibrated automatically but
must be verified after a new pump installation and
before performing any boom speed calibrations.
Refer to Repair Procedures,
Calibration Process
Steps.
This procedure determines the number of
revolutions that are required to create a
determined amount of flow for both the large and
small gear pumps.
Note: Start this procedure with the secondary
boom in the stowed position and primary boom at
or above horizontal. Position the machine in a
suitable location with sufficient vertical space.
Refer to Navigation Menus,
Settings Menu.
Note: Primary angle sensor must be functional and
calibrated. Refer to Repair Procedures,
How to
Calibrate Booms Angle Sensor.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
Note: If the unit is equipped with the engine option,
set the machine to DC mode.
2 Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
3 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
4 Momentarily activate steer in the right
direction until SETTINGS is shown on the
display.
5 Momentarily activate the drive enable toggle
switch in the right direction until you see the
VALVE AND SENSOR SETTINGS screen.
6 Momentarily activate the drive enable toggle
switch in the right direction until CALIBRATE
TILT SENSOR is shown on the display.
7 Continue to momentarily active the steer in
the right direction until LARGE & SMALL
PUMP EFFICIENCY is shown on the display.
8 Momentarily activate the drive enable toggle
switch to enter LARGE & SMALL PUMP
EFFICIENCY menu.
9 Fully elevate the primary boom.
Result: A one second pulse alarm will sound
indicating a successful pump efficiency
calibration. The display will indicate pump
efficiency in %.
10 Fully lower the primary boom.
Result: A one second pulse alarm will sound
indicating a successful pump efficiency
calibration. The display will indicate pump
efficiency in %.
To exit programming mode:
11 Move and hold the drive enable toggle in the
left position until the display returns to
SYSTEM READY mode.
Содержание Genie S-60 DC
Страница 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Страница 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Страница 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Страница 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Страница 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Страница 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Страница 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Страница 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Страница 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Страница 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Страница 171: ......