Service and Repair Manual
July 2021
Drive Control Fault Codes
112
S
®
-60 DC • S
®
-60 FE
Part No. 1299608GT
CAN
Object
Flash
Pattern
Description &
Fault Type
Cause
Effect
Solution
2102
3-11
Motor
Misalignment
Error
Motor offset has shifted so
controller is producing
torque in an uncommanded
direction
Shudown Vehicle;
Clear:
Reset Controller
2830
4-6
NV Memory
Failure
Fault Type(s):
1 = Invalid
checksum
2 = NV write failed
3 = NV read failed
4 = NV write did
not complete
during power
down
1. Failure to read or write to
nonvolatile (NV) memory
2. Internal controller fault
ShutdownAll:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
ShutdownInterlock
ShutdownDriver1 to 7
ShutdownPD
FullBrake
ShutdownPump
ShutdownCoilSupply
ShutdownVehicle
ShutdownLower
ShutdownLift
Set: Controller operating system tried
to read or write to EEPROM memory
and failed
Clear: Download the correct software
and matching parameter default
settings into the controller and Reset
Controller
2211
4-7 HPD Sequencing
1. Incorrect sequence in
application of Keyswitch,
Interlock, Direction, or
Throttle
2. Faulty wiring, crimps, or
switches at KSI, Interlock,
Direction, or Throttle
3. Moisture in above-noted
digital input switches
causing invalid (real)
On/Off state
Verify input switch status.
See Programmer » System
Monitor menu » Inputs »
Switch Status
Verify Throttle. See
Programmer » System
Monitor menu » Inputs »
Throttle Command
ShutdownThrottle
Set: HPD (High Pedal Disable) or
SRO (Static Return to Off)
sequencing fault caused by incorrect
sequence of KSI, interlock, direction,
and throttle inputs
Clear: Reapply inputs in correct
sequence
2460
4-7
Emergency
Reverse High
Pedal HPD
Emergency Reverse
operation has concluded,
but the throttle, forward and
reverse inputs, and
interlock have not been
returned to neutral
ShutdownThrottle
ShutdownEMBrake
Dual Drive
Same, both motors
Set: At the conclusion of Emergency
Reverse, the fault was set because
various inputs were not returned to
neutral
Clear:
If EMR_Interlock = On, clear the
interlock, throttle, and direction inputs
If EMR_Interlock = Off, clear the
throttle and direction inputs
Содержание Genie S-60 DC
Страница 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Страница 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Страница 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Страница 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Страница 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Страница 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Страница 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Страница 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Страница 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Страница 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Страница 171: ......