-60 FE
21
7 Momentarily activate steer in the right
direction until BOOM ANGLE CALIBRATE is
shown on the display.
8 Momentarily activate the drive enable toggle
switch in the right direction to enter the BOOM
ANGLE CALIBRATE screen.
9 Momentarily activate the drive enable toggle
switch in the right direction to enter the sub-
menu.
Result: The screen will display PRI SNSR
MVXXXX. A flashing value indicates the mV
(millivolt) value is within expected range.
10 Momentarily activate the drive enable toggle
switch in the right direction to store the
millivolt value.
Result: An alarm will sound for one second
and the screen will display CALIBRATED.
11 Calibrate the boom elevated positions, fully
raise the primary boom. Repeat steps 9 and
10 to store the millivolt value.
Result: An alarm will sound for two seconds
and the screen will display CALIBRATED
indicating both the primary and secondary
angle sensors have been calibrated
successfully.
To exit programming mode:
12 Move and hold the drive enable toggle in the
left position until the display returns to
SYSTEM READY mode.
1-3
How to Clear Fault History
There are 1 thru 16 fault codes shown in the fault
history menu, 1 being the most recent displayed. It
may be necessary to clear the fault history in order
to acquire the most recent fault codes. It is also
good practice to clear fault history after performing
any calibration procedure.
Note: Perform this procedure with the boom in the
stowed position. Refer to Navigation Menus,
Faults Menu
.
1 Turn the key switch to platform controls. Do
not start the engine (if equipped).
2 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
3 Do not press down the foot switch.
4 Move and hold the drive enable toggle switch
in the right direction while holding steer in the
right direction.
5 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer joystick.
Result: The display will show FAULTS.
6 Momentarily activate the drive enable toggle
switch in the right direction until ACTIVE
FAULTS is shown on the display.
7 Momentarily activate steer in the right
direction until FAULT HISTORY is shown on
the display.
8 Momentarily activate the drive enable toggle
switch in the right direction to activate the
clear fault history function.
Result: The display will read ENABLE at the
bottom.
9 Momentarily activate steer in the right
direction to change NO to YES on the display.
10 Momentarily activate the drive enable toggle
switch to except the change.
Result: The alarm will sound indicating the
fault history has been cleared.
Содержание Genie S-60 DC
Страница 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Страница 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Страница 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Страница 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Страница 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Страница 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Страница 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Страница 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Страница 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Страница 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Страница 171: ......