July 2021
Service and Repair Manual
Drive Control Fault Codes
Part No. 1299608GT
S
®
-60 DC • S
®
-60 FE
105
CAN
Object
Flash
Pattern
Description &
Fault Type
Cause
Effect
Solution
2510
1-2
Controller
Overcurrent
1 = Controller
Over Current
Phase U
2 = Controller
Over Current
Phase W
3 = Controller
Over Current
Phase V
4 = Irms > 135%
Current Limit
1. External short of phase U,
V, or W motor connections
2. Speed encoder noise
problems
3. Motor parameters are
mistuned
4. Controller defective
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Reset Controller
2832
1-3
Current Sensor
Fault
1. Leakage to vehicle frame
from phase U, V, or W (short
in motor stator)
2. Controller defective
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: Controller current sensors
have invalid offset reading
Clear:
Reset Controller
2223
1-4
Precharge Failed
1 = Abort
2 = Energy Limit
Exceeded
3 = Time Limit
Exceeded
An external load on the
capacitor bank (B+
connection terminal) that
prevents the capacitor bank
from charging
See Programmer » System
Monitor menu » Controller »
Capacitor Voltage
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: The precharge failed to
charge the capacitor bank
Clear: Cycle Interlock or Reset
Controller
2141
1-5
Controller Severe
Undertemp
Controller is operating in an
extreme environment
See Programmer » System
Monitor menu » Controller »
Controller Temperature
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: Heatsink temperature below
–40°C (–40°F)
Clear: Bring the heatsink
temperature above –40°C (–
40°F) and then Reset
Controller
2142
1-6
Controller Severe
Overtemp
Controller is operating in an
extreme environment.
Excessive load on vehicle
Improper mounting of
controller
See Programmer » System
Monitor menu » Controller »
Controller Temperature
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: Heatsink temperature above
+95°C
Clear: Bring heatsink
temperature below +95°C, and
then Reset Controller
Содержание Genie S-60 DC
Страница 151: ...July 2021 Service and Repair Manual 139 Electrical Schematic DC FE Models ...
Страница 154: ...Service and Repair Manual July 2021 142 Electrical Schematic Ground Control Box ...
Страница 155: ...July 2021 Service and Repair Manual 143 Electrical Schematic Turntable Controller ...
Страница 158: ...Service and Repair Manual July 2021 146 Electrical Schematic Platform Control Box ...
Страница 159: ...July 2021 Service and Repair Manual 147 Electrical Schematic Kubota D1105 ...
Страница 162: ...Service and Repair Manual July 2021 150 CAN BUS Wiring Diagram ...
Страница 163: ...July 2021 Service and Repair Manual 151 Power Cable Wiring Diagram ...
Страница 165: ...July 2021 Service and Repair Manual 153 Wiring Diagram AC Power Options ...
Страница 168: ...Service and Repair Manual July 2021 156 Wiring Diagram RCBO Options ...
Страница 169: ...July 2021 Service and Repair Manual 157 Hydraulic Schematic DC FE Models ...
Страница 171: ......