7.2 

How to set the Unicast/Multicast output 

 
If  the  IP  hardware  board  is  configured  as  IP  Input,  please  follow  below  procedure  to  change  it  to  IP 
output: 
 

1.  Only on the front panel is accessible, go to  

 

Main Menu -> System -> Optional function -> External board type -> IP Out 

 

2.  Switch off the unit, and then switch it on again. Then the unit will become IP Out, and the 

FACTORY DEFAULT setting will not change this IP direction. And at the same time, the menu 
structure on front panel & HDMS (the PC management software) will be changed accordingly.  

 
To set Unicast/Multicast output, please follow the procedure below: 
 

1.  Go to the Main menu -> Output -> Ethernet 

 

2.  Set the IP address & parameters for the IP hardware board: Stream IP    

address -> enter the IP address for this IP hardware board (should be the same network 
section of the Stream Gateway, this depends on the characteristic of the gateway)  

 

Stream Netmask -> enter the network submask for this IP hardware board 

 

Stream Gateway -> enter the Gateway address for this IP hardware board 

 

Stream MAC address -> Show the MAC address of this IP hardware board, read only. 

 

3.  Set the universal parameters for the output IP stream. On the same sub menu:   

Gate MAC address -> here the MAC address must be set as the MAC address of the Gateway 
where DCH-510P™ is located.   
Protocol -> enter the protocol of the output stream, DCH-510P™ supports UDP and RTP.  
TS Pkts per UDP -> set the quantity of TS packages that will be carried IP package. The 
range goes from 1 ~ 7   
Time to Live -> set the TTL for the output IP package.    
Type of Service -> set the type of service for the output IP stream 

 

Source -> set the wanted stream output via IP.   
Mode -> Set the IP output mode as IPTV mode or DVB mode. 

 

4.  If the mode is set to be DVB mode, please follow below procedure ‘DVB mode’. If the mode is 

set to be IPTV mode, please go to procedure ‘IPTV mode’ directly. 

 

DVB mode: 

Unicast/Multicast Setup -> set the address and port parameters for the IP stream. Press Enter to go to 
the submenu. As below: 
 

 

Multicast IP -> enter the multicast IP address for the output stream. 

 

 

Multicast UDP Port -> enter the port number of the output stream. 

 

 

Target Mac address-> set the MAC address of the receiving device. The parameter will be 

used only when the receiving device is located under the same gateway. The parameter will 
be ignored by DCH-510P™ if the receiving device is located under other remote network or 
under different gateway. 

 

Содержание DCH-510P

Страница 1: ...ser Guide V1 1 1 D DC CH H 5 51 10 0P P User Guide V1 1 Teracue AG Schlossstr 18 85235 Odelzhausen Germany Tel 49 0 8134 555 10 Fax 49 0 8134 555 199 info teracue com www teracue com Document Version...

Страница 2: ...DCH 510P User Guide V1 1 2...

Страница 3: ...ion Documents are located at www teracue com support If you find some points in this document unclear then please let us know so we can improve this documentation Thank you Mail to documentation terac...

Страница 4: ...nd users to install the DCH 510P on their computer If you received this publication as a PDF then it s a good idea to print it out for future reference It is best to use this user guide directly in fr...

Страница 5: ...5 1 2 DVB S2 Menu 10 5 1 3 RSSI 10 5 1 4 Ethernet Menu 11 5 2 OUTPUT MENU 11 5 2 1 BISS Menu 12 5 2 2 CI Menu 12 5 2 3 Decoder 13 5 2 4 ASI 15 5 2 5 ASI2 15 5 2 6 SDI 15 5 2 7 MUX 16 5 2 8 Ethernet 1...

Страница 6: ...icing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that safety protection is impaired the device must be m...

Страница 7: ...tion 3 1 Inspection Open the packaging box check if all appendixes are in the box according to the appendix list and if the device has any visible damage please contact the agent 3 2 Operating Voltage...

Страница 8: ...nting information MANAGEMENT LAN port for software update ASI OUT2 Group2 ASI output port one for back up ASI OUT1 Group1 ASI output port one for back up ASI1 IN ASI1 input port ASI2 IN ASI2 input por...

Страница 9: ...power is OK TUNER LOCK Tuner lock indicator green light means signal is locked if there is no light which means no signal input or wrong parameters setting ALARM Alarm indicator LCD 2 20 character LCD...

Страница 10: ...pears when the External Function is set as IP IN Please refer to chapter 5 3 6 for setting method 5 1 2 DVB S2 Menu There are 6 options to set DVB S2 parameters After signal is locked the TUNER LOCK i...

Страница 11: ...you can not configure the address Multicast IP Addr Enter the IP address of the multicast stream for the transport stream over IP Multicast UDP Port Enter the UDP port number of the TS over IP stream...

Страница 12: ...chapter 5 2 7 for details to set the signal source of descrambling press ENTER key to save or press EXIT key to scrap Setup under this sub menu you can see all program names from the source of CI tha...

Страница 13: ...unction is enabled and turned on Refer to chapter 5 2 7 and chapter 5 3 6 for how to set the built in MUX Press ENTER key to save or press EXIT key to scrap A few seconds after the source being select...

Страница 14: ...ails You can select Black Screen or No Sync or Still Picture Audio You can configure the audio settings in the submenu Audio1 Level Use the keys to modify the audio1 level within this range 0 99 Audio...

Страница 15: ...input port will be delivered to the ASI2 output port on the back panel MUX TS The transport stream comes from built in MUX and will be delivered to the ASI output port on the back panel The MUX TS is...

Страница 16: ...se keys to roll up the program names and use keys to switch among input sources where a number in front of the program name indicates the input source 0 xxxxx Displays the program name which comes fro...

Страница 17: ...r the output IP stream Source set the wanted stream output via IP The stream could be from one of the following combinations ASI1 Input ASI2 Input CI Decrypted MUX TS note the MUX TS is showed only wh...

Страница 18: ...number Press ENTER key to go down to the sub menu There are 4 sub menus x Multicast IP Enter the multicast IP address for the output stream for the addresses inside 224 0 0 1 to 239 255 255 255 are b...

Страница 19: ...teway set the gateway for the network to which this unit is connected 5 3 2 Trap IP Address The DCH 510P provides a Monitor Center IP address You can set this to be the same IP address of the Monitor...

Страница 20: ...NTER key to active the menu use keys to configure the TS IP portion as IP in or IP out or No Exist and the option is exclusive Press ENTER key to confirm or to scrap by pressing EXIT key After the ope...

Страница 21: ...ff FEC code rate 1 2 2 3 3 4 5 6 7 8 Input frequency 470 862MHz UHF 174 230MHz VHF Input level 20 70dBmV Input impedance 75 IEC Female TS over IP I O Ethernet Connector RJ45 10 100M Max bit rate 70Mbi...

Страница 22: ...80ix60 1080ix59 94 CVBS port 576ix50 480ix60 Management Ethernet Connector RJ45 10 100M for NMS and software upgrade Protocol SNMP TCP IP HTTP Front panel control LCD display and keypad General Power...

Страница 23: ...acteristic of the gateway Stream Netmask enter the network submask for this IP hardware board Stream Gateway enter the Gateway address for this IP hardware board Stream MAC addr Show the MAC address o...

Страница 24: ...read only 3 Set the universal parameters for the output IP stream On the same sub menu Gate MAC address here the MAC address must be set as the MAC address of the Gateway where DCH 510P is located Pr...

Страница 25: ...get MAC address set the MAC address of the receiving device The parameter will be used only when the receiving device is located under the same gateway The parameter will be ignored by DCH 510P if the...

Страница 26: ...DCH 510P User Guide V1 1 26...

Страница 27: ...DCH 510P User Guide V1 1 27...

Страница 28: ...DCH 510P User Guide V1 1 28...

Страница 29: ...DCH 510P User Guide V1 1 29...

Страница 30: ...rrent emissions equipment input current 16 A per phase EN 61000 3 3 2008 Electromagnetic compatibility Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage suppl...

Отзывы: