MAINTENANCE
53
EZ Rider 330730 (9--00)
SOLUTION SYSTEM
RECOVERY TANK
The recovery tank holds recovered solution. Clean
and drain the recovery tank after each use. The
outside of the tank can be cleaned with vinyl
cleaner.
NOTE:
DO NOT
use steam to clean the tanks.
Excessive heat can damage the tanks and
components.
Thoroughly rinse the pressure switches inside the
recovery tank after each use.
The vacuum fan inlet filter is located above the
recovery tank, on the inside of the tank cover.
Check the vacuum fan inlet filter daily. Clean inlet
filter with a damp cloth or hose when dirty. Allow
filter to dry completely before replacing it into
machine.
SOLUTION TANK
The solution tank holds the cleaning solution.
If deposits form on the bottom of the tank, rinse
the tank and with a strong blast of warm water.
A solution filter is located under the machine near
the solution control valve. If the filter becomes
dirty, the solution flow will be reduced. Check and
clean this filter regularly.
NOTE:
DO NOT
use steam to clean the tanks.
Excessive heat can damage the tanks and
components.