SWEEPING
3-8
3640G/LP 330585 (5--00)
4. Remove the two self threading hex screws
holding the Thermo Sentry
t
to the panel.
Remove the Thermo Sentry
t
.
5. Position the new Thermo Sentry
t
on the
panel. Reinstall the hardware and lightly
hand tighten.
6. Reconnect the wires to the Thermo
Sentry
t
. See schematic in the
ELECTRICAL section.
7. Close the cover.
VACUUM WAND
The vacuum wand uses the machine’s vacuum
system. Use the vacuum wand to pick up debris in
narrow or partially enclosed areas that cannot be
swept by the machine.
NOTE: The vacuum hose screws into the vacuum
nozzle (left hand thread). Un--screw to replace the
hose.