10
11
4. Operating modes
Auto Mode (Start)
Auto mode is normal operation mode in which the temperature is controlled
and maintained automatically in accordance with the set degree.
Stand-By Mode
Administrator can decrease setting temperature of the machine on pause
time and turn the temperature back automatically after passing the pause
time. You can save the electric energy.
When you start [Stand By Mode], Value of [Setting temperature (SV)] is
changed to temperature of Stand By Mode ( % rate, [Stand By Output] of
[Advanced setting 2]) and it runs for [System Setting] [Stand by Hour/Minute]
setting time.
It will turn back to the [Auto Mode] After the [Stand by Hour/Minute].
Boost Mode
This is the function to output with setting value of [Maximum output of
Boost %] to approach to the [Setting temperature (SV)] quickly without [PID
control]
When you start [Boost Mode], timer will start running and it will turn to
[Stop Mode] after running as much as minutes that set up for [Boost Minute]
on the [System setting] Screen
Manual Out
It is emergency mode that can be automatically worked by manual out mode
even if it occur sensor open, short and reverse.
1. Check Up status of wiring of connector that connected to the Mold
and type of thermocouple(T/C). (Check up that wiring of the thermocou-
ple and heater is separated and wiring is toward from the heater to the
thermocouple.)
2. Check up resistance of heater, status of insulation and open of ther-
mocouple.
3. Check up that specification of connecting cable.
4. Connect connecting cable after Mold is installed on injection machine.
5. Check up that input voltage (240V/380V) and setting voltage of con-
troller are same and if so, connect the power cable. (You can find the
voltage of the controller from the label on the Controller case.)
6. A Ground wire of controller MUST be grounded.
(It prevents from electric shock, fuse and triac broken by noise voltage.)
7. Turn the main power ON.
8. Check up that temperature is approached to the setting temperature
with clicking Start Button. (It is more safety to use it after self inspection
checking such as wiring, heater and T/C)
Warning : You ALWAYS NEED to check that fan is working or not
since if the fan under the controller is stopped, it causes malfunction.
3. Check up list and operate order
before using the controller
Содержание TC-3200 Lite
Страница 1: ...TC 3200 Lite Ver 1 1 ENG Instruction Manual...
Страница 23: ...44 45 11 2 380V 440V 3Phase 4 Line Type 11 3 240V 1 Phase 2 Line Type...
Страница 27: ...52 53...