48
49
13. Check points for the trouble shooting
No
Phenomenon
Probable cause
Check Point
1
error code
[ TC Op ] display
- Sensor(T/C) was
Disconnected.
- Check T/C wire with tester.
If disconnected, replace it.
2
error code
[ TC St ] display
- Sensor(T/C) wire
is short on output
side
- Check whether T/C wire is
mal-contacted at connector or
pressed by mold
3
error code
[ TC Re ] display
- +/- polarity of
sensor (T/C) is
changed.
-After Checking the condition
of connection in connector
attached to mold and change
polarity of T/C
4
error code
[ HT Op ] display
- Heater was
Disconnected
-Check resistance of heater
with tester.
If it is blown out, replace
heater
5
error code
[ HT St ] display
- Short circuit in
heater or capacity
of heater is higher
than upper limit of
current
- Check short or open of
heater with tester
- Change the capacity of
heater that is lower than 20A
6
error code
[ TR St ] display
- TRIAC attached to
heat radiator board
is damaged
- Check pin in TRIAC
- If 2 or 3 pins are short, it is
malfunctioned.
7
error code
[ FU1 Op ] display
- F-1 fuse is discon-
nected by momen-
tary over-current
- Replace F-1 fuse. (250V 20A)
8
error code
[ FU2 Op ] display
- F-2 fuse is discon-
nected by momen-
tary over-current
- Replace F-2 fuse. (250V 20A)
9
Temperature rises
continuously
- TRIAC attached to
heat sink of con-
troller is damaged.
- Check pin in TRIAC
- (2 or 3 pins are short, it is
malfunctioned.)
No
Phenomenon
Probable cause
Check Point
10
Temperature
drops
continuously
- FS1 or FS2 fuse
open
- Heater open
- the part of wire in
heater is opened
- Sensor (T/C) open
- Change fuse (250V 20A)
- Check resistance of heater
with tester
- Check heater open
11
Severe Tem-
perature (De-
viation between
SetTemp&Sensing
Temp.)
- Sensor Contact is
unstable
- Sensor type is dif-
ferent in each other
- Check contact state of
sensor
- Check sensor type
- Try to re-tuning
12
Controller Tem-
perature doesn’t
rises,
But heater in ac-
tua mold is over
heated
T/C wire is pressed
by mold or it’s coat
is peeled, so as to
contact mold or line
Check T/C wire and replace it
13
Setting tempera-
ture of controller
equals with pre-
sent temperature,
but the heater
in actual mold
is overheated or
cold.
T/C (sensor) type
between mold and
controller is differ-
ent. ex) CA(K)→IC(J)
IC(J)→CA(K))
Make T/C (sensor) type of
mold equal with that of
controller.