28
29
⑤ Boost (Minute):
It will turn to [Stop Mode] after the setting Minute
on the Boost Mode.
⑥ Setup Lock Function:
This is the function to lock the system NOT normal
user to change Advanced Setup and some System Setup.
* Setting that affected by Setup Lock Function
→ [Basic Setup]: [Advanced Setup 1] / [Advanced Setup 2]
→ [System Setup]: [Alarm] / [LANGUAGE] / [Administrator] / [Timer Program]
⑦ Protecting overheat function:
This is the function which is automatically
able to detect the time of temporary checking or pause. Regarding this, it
protects from overheat of mold and burning or over-temperature resin by con-
verting (Stand-by condition)
⑧ Balance control:
It prevents from overheat of mold or burning or over-
temperature resin in ready time by raising all of zones of setting temperature
value at the same time according to heaters capacity and status.
⑨ Alarm:
If you use Alarm function, Alarm function will run when system has
error.
⑩ LANGUAGE:
You can change display language according to your language.
⑪ Setting in details:
It browses setting in details display in order to set details
in each setting
⑫ Administrator:
You open administrator mode.
⑬ Timer program:
If sequence injection timer is installed, you can select and
control it.
ex) In case (Set Temp:SV) : 200 ℃, t(Stand-By Hour) : 1 hour (1:00),
P (Standby out) : 70 %
☞ Stand-By mode is 140 which is 70% of mode set temperature.
7.4. Mold File
① Load:
It will load the saved Mold File in the [Memory] or [USB Stick].
② Save:
It will save the loaded mold file or save the file with other name.
③ Delete:
It will delete the saved Mold File in the [Memory] or [USB Stick].
④ Number of Zone:
It will set a number of zones.
⑤ Number of gate:
It will set a number of gates.
⑥ Mode Test:
You can test the Mold.
⑦ Checking Window for zone status:
It will display setting temperature of
each zone and status of current communication.
7.4.1. Mold File setting
④
①
②
③
⑦
⑥
[Mode File] is setting for Mold. You can set on each Mold. Even if Mold is
changed, you can load the existed setting without setup again. You can set
when you click [Mold File] on [Main Screen].
⑤
Содержание TC-3200 Lite