48
Input properties
:
Identifier
: the identifiers of the inputs cannot be changed. They are used for identification of the
inputs in the program.
Input type
: the input can be normally open (
NO
), or normally closed (
NC
).
When set to
NO
, an input event will be generated when the open contact between the given input
(
IN1
…
IN4/IN6
) and the
V-
terminal (DC power negative) becomes closed.
When set to
NC
, an input event will be generated when the closed contact between the given input
(
IN1
…
IN4/IN6
) and the
V-
terminal (DC power negative) becomes open.
Sensitivity / Unit of measure
: state changes of the input shorter than the value entered in this
section with regard to activation of the input are ignored by the device. The unit of measure can
also be selected (milliseconds, seconds or minutes).
Restore sensitivity / Unit of measure
: state changes of the input shorter than the value entered
in this section with regard to restoration of the input are ignored by the device. The unit of measure
can also be selected (milliseconds, seconds or minutes).
Delay settings:
Entry delay
: in this section you can configure the time available to disarm the device after violating
the given zone. The device ignores state changes of the given input for the time of the entry delay,
so input event will not be generated until the time expires. If the time expires and the system is
still armed, an input event will be generated. The entry delay can be configured in seconds.
Exit delay
: in this section you can configure the time for which state changes of the given input
will be ignored after arming the device. If the given zone is violated during the exit delay, input
event will not be generated. The exit delay can be configured in seconds.
Zone options:
24h zone
: if this option is enabled, the given input becomes armed continuously and does not
disarm when the device is disarmed. State changes of the given input will generate input events
even if the device is disarmed.
Auto shutdown
: if this option is enabled, generating events by the given input will be limited
according to the “
Limitation of alarms
” settings in the “
General
”
settings
menu. The device will
ignore state changes of the given input after the number of events generated by it reaches the
configured limit. For further details please read the specification of the mentioned settings.
If disabled, the given input can generate unlimited number of events.
Force
: if this option is enabled the device will ignore the state of the given input upon arming.
If the given input is activated upon arming the device, it will become armed after it restores.
If this option is disabled, arming will be forbidden if the given input is activated.
Follow
: if this option is enabled, the given input will take over the properties (entry delay, instant)
of the first violated zone (input) after arming. If entry delay is configured for the first violated zone,
the follow zone will use the same entry delay, or if the first violated zone is instant
(no entry delay is configured for the given zone), the follow zone will be instant too.
Click “
OK
” to accept the changes or “
Cancel
” to quit without saving.