SE868Kx-Ax Family Product User Guide
1VV0301201 Rev. 5
Page 70 of 83
2021-07-15
Not Subject to NDA
15.
ENVIRONMENTAL REQUIREMENTS
Operating Environmental Limits
Operating Environmental Limits
Temperature
-40°C to +85°C
Temperature Rate of Change
±1°C / minute maximum
Humidity
Up to 95% non-condensing or a wet bulb temperature
of +35°C, whichever is less
Maximum Vehicle Dynamics
600 m/sec (acquisition and navigation)
2G acceleration
Table 33: SE868 Family Operating Environmental Limits
Storage Environmental Limits
Storage Environmental Limits
Temperature
-40°C to +85°C
Humidity
Up to 95% non-condensing or a wet bulb temperature
of +35°C, whichever is less
Shock
18 G peak, 5 millisecond duration
Shock (in shipping container)
10 drops from 75 cm onto concrete floor
Table 34: SE868 Family Storage Environmental Limits