SE868Kx-Ax Family Product User Guide
1VV0301201 Rev. 5
Page 46 of 83
2021-07-15
Not Subject to NDA
This allows the module to retain time and ephemeris information, thus enabling hot and
warm starts, which will improve (decrease) TTFF.
9.4.3.
DC Power Requirements
Main Supply Voltage & Backup Voltage
Supply
Name
Min
Typ
Max
Units
Vcc and Vbatt
Vcc & Vbatt
2.8
3.3
4.3
V
The drop from 2.7 V to 0 V must be > 1 ms.
Also, keep the supply ripple as low as possible (< 50 mV)
Table 23:DC Supply Voltage
9.4.4.
DC Power Consumption: SE868-A
State & Constellation
Typ
Max
Units
Acquisition
GPS Only
84
123
mW
GPS and Glonass
103
146
mW
Navigation/Tracking
GPS Only
74
120
mW
GPS and Glonass
81
139
mW
Low Power Mode
–
Always Locate
GPS Only
19
mW
GPS and Glonass
25
mW
Vbatt
50
99
μ
W
Operating temperature: 25°C
Supply voltages: 3.3 VDC nominal
SBAS: enabled
1PPS sync: enabled
Table 24: SE868-A Power Consumption