C-2000 and C-2000HS Technical Manual
Setup 39
Bosch Security Systems, Inc.
Technical Manual
F.01U.174.927 Rev 03
To
program the sequence to decode on receive for EMSTEL mode
, do the following:
1.
Scroll to
setup option
16.
2.
Program the desired
sequence
in the slot used for that function.
For example: to program 1234567890 to be transmitted when the D10 sequence number is entered, do the following:
1.
Scroll to
setup option
11.
2.
Press
ENTER (#).
3.
Enter
1,2,3,4,5,6,7,8,9,0
.
4.
Enter
A
.
NOTE:
The setup option is used to select which Dxx address the sequence is intended for. The A is only a secondary
enter key, allowing the # key to be a part of any sequence.
To
disable a previously programmed sequence
, do the following:
1.
Select the
setup option
using FUP/FDWN keys.
2.
Press
ENTER (#).
3.
Press the
B
key.
Display shows OC (Option Changed)
.
NOTE:
Allowed keys are (1234567890*#). The maximum sequence length is 16 digits.
Delays are added to the sequence by pressing the D key during the sequence entry period. For example, the number 111 - - 555
- - 1234 can be entered as follows: 1 1 1 D D 5 5 5 D D 1 2 3 4, which takes up 14 of the 16 total digits. When entering a
sequence, the display will show the sequence count of the current DTMF string.
Setup State 45 Ring Duration (Special Software Option)
The
Ring Duration
is used to program the number of rings that occur if the unit is instructed to ring and is not taken offhook.
Ringing stops after the programmed number of rings. The setup options are 1–10 corresponding to the number of desired rings.
The default value is four (4) rings. This feature is used in SF and EMSTEL modes.
To
program the ring duration
, do the following:
1.
Select the
setup option
using FUP/FDWN keys.
2.
Press
ENTER (#).
Display shows OC (Option Changed)
.
Dial String Entered
1
1
1
D
D
5
5
5
D
D
1
2
3
4
Display Count
1
2
3
4
5
6
7
8
9
10
11
12
13
14