Setup State 14 DTMF Hang Timer
The
DTMF Hang Timer
setup state is used to allow the user a programmable amount of time to release one (1) DTMF key
and press another without the hold tone being stopped and requiring the unit to resend the guard. Function tones
can vary from
0 to 980ms and is configurable to the nearest 10ms. This timer has no effect if PTT or IC is already pressed.
Setup State 15 MIC AGC Enable/Disable
The
MIC AGC Enable/Disable
is used to enable/disable AGC on all MIC inputs.
Setup State option:
1=Enable*
2=Disable
To
enable/disable AGC on all MIC inputs
, do the following:
1.
Select the
setup option
using FUP/FDWN keys.
2.
Press
Enter (#).
Display shows OC (Option Changed).
Setup State 16 RX AGC Enable/Disable
The
RX AGC Enable/Disable
is used to enable/disable AGC on the receive audio.
Setup State option:
1=Enable*
2=Disable
To
enable/disable AGC on the receive audio
, do the following:
1.
Select the
setup option
using FUP/FDWN keys.
2.
Press
Enter (#).
Display shows OC (Option Changed).
TABLE 14.
DTMF Hang Time
Option
Duration
1
0 ms
5
40ms
51 (default)
500ms
99