Bosch Security Systems, Inc.
Technical Manual
F.01U.174.927 Rev 03
CHAPTER 3
Setup
Setup Mode
Entering Setup Mode
Entry into the C-2000
Setup Mode
is accomplished by pressing and holding the
IC
and
MON
keys, then pressing the
2
key.
The IC and MON buttons stay lit when in setup mode.
If a PIN number is required, an EP (Enter PIN) appears in the display requesting the 4-digit number be entered. If the number
is entered incorrectly, the C-2000 displays
“
IP” (Incorrect PIN) and returns to user mode. No PIN number is required if the
system defaults are set. Default values can be restored to the unit by pressing and holding the function up and function down
keys when power is applied to the unit. If a PIN number has been set, it is requested before resetting to default values.
If the PIN is entered incorrectly, the C-2000 does not reset its values to default and will enter the user mode.
PIN numbers can be enabled, disabled, or changed in Setup Mode, see Setup State 1 PIN Number Change on page 21.
If the PIN number is lost or forgotten, a system override is available that sets all parameters back to default.
To
reset the system parameters
, do the following:
3.
Power down the
unit
.
4.
Open the
case.
5.
Disconnect the
speaker.
6.
Place
test jumper J17
in the A position.
7.
Power up the
unit
.
This mode resets defaults and does a system test. The C-2000 has now stored system defaults, which includes no PIN
number.
8.
Power down the
unit
.
9.
Place
J17
in the B position.
10.
Connect the
speaker.
11.
Close the
case.
12.
Power up the
unit
.