![Telenetics Corporation FT100 S Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/telenetics-corporation/ft100-s/ft100-s_installation-and-operation-manual_1082085098.webp)
Control Port Operation
6-20
FT 100S
PERFORMANCE HISTORY
The FT 100S continuously monitors the network received signal for
error conditions and alarms.
Performance history information is stored in nonvolatile memory and
can be accessed and displayed by the local user or transmitted to a
remote FT 100S or other T1 terminating facility used for network
management.
Entering PC
carrier performance history
or
PU user performance history
displays the carrier or user performance history menu.
These two main menus for performance history are described after the
sections that list and describe the various error conditions.
ERROR CONDITION CATEGORIES
The unit monitors these error events:
•
ESF error count
•
SF error count
•
Errored seconds
•
Bursty errored seconds
•
Severely errored seconds
•
Unavailable seconds
•
Loss of frame count
•
Controlled slip second
•
Line code violation seconds
•
% error free seconds
Error Events
ESF Error Count (ESF framing only) contains a count of ESF error
events. An ESF error event is either a CRC error or an Out of Frame
Error (OOF).
Содержание FT100 S
Страница 10: ...ESF Framing C 4 Framing Format Conversion C 6 Performance Monitoring C 6 Service and Support...
Страница 22: ...Installation 2 8 FT 100S...
Страница 28: ...Hardware Configuration 3 6 FT100S...
Страница 106: ...Control Port Operation 6 28 FT 100S...
Страница 108: ...Maintenance 7 2 FT 100S...
Страница 116: ...Specifications A 4 FT 100S...
Страница 120: ...Control Port Command Quick Reference B 4 FT 100S...
Страница 128: ...T1 Overview C 8 FT 100S...