![Telenetics Corporation FT100 S Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/telenetics-corporation/ft100-s/ft100-s_installation-and-operation-manual_1082085052.webp)
Front Panel Option Selection
4-24
FT 100S
Bit Errors Display
When a test includes a test pattern (RLTP or TP), this display shows the
number of errored bits received since the test was entered or restarted.
PUSHBUTTON ACTION:
YES-
No action
NO-
Advances to average BER display
HOME-
Returns to the top of the present test menu
Average Bit Error Rate Display
This display shows the average number of errored bits received since
the test was entered or restarted. The value appears in exponential nota-
tion.
Avg Ber = # of bit errors
total bits received
PUSHBUTTON ACTION:
YES-
No action
NO-
Advances to the elapsed seconds display
HOME-
Returns to the top of the present test menu
Elapsed Seconds Display
This display shows the number of seconds that have elapsed since the
test was entered or restarted.
DTE Test Pat
Bit Errors:
nnnnnn
DTE Test Pat
Avg. BER:
n.nE-nn
DTE Test Pat
Elapsed Sec.:
nnnnn