09420A DCN8343
Teledyne API Model 480M O
3
Monitor User Manual
49
7.7. SENSOR MODULE REPLACEMENT
The module can be replaced by first disconnecting the electronic connectors from
the sensor PCA that run to J13 (Bench Supply) and J10 (Bench Serial Interface) on
the Mainboard, and by disconnecting the pneumatic tubing at the sample filter and
at the input to the scrubber. Then remove the four large socket head screws (Figure
7-6) that hold the mounting bracket in place. Do the reverse to install the
replacement module.
Figure 7-6. Sensor Module Removal