Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide –
Preliminary Version
Page 72
A
Belden
Brand
Display Mode
Typical
Readout
Base Station Digital Display Activity Explanation
DIAGNOSTIC MODE
Temperature (TEMP)
DIAG
When first entering the Diagnostic mode the DIAG display mode indicator
LED will blink – the first sub-mode is TEMP (Temperature). The Digital
Display Characters will glow
Green
when the temperature is normal and
Red
when outside of normal range.
DIAG/TEMP
TEMP
Indicates the display is in the TEMP sub-mode
DIAG/TEMP
PS
The Power Supply (PS) temperature will be displayed
DIAG/TEMP
TEMP
Repeats that the display is in the TEMP sub-mode
DIAG/TEMP
37C
Temperature display in Centigrade for Power Supply circuit board
DIAG/TEMP
BASE
The Base Station main circuit board temperature will be displayed
DIAG/TEMP
TEMP
Repeats that the display is in the TEMP sub-mode
DIAG/TEMP
47C
Temperature display in Centigrade for Base Station circuit board
DIAG/TEMP
PS
The Power Supply (PS) temperature will be again displayed
DIAG/TEMP
TEMP
Repeats that the display is in the TEMP sub-mode
DIAG/TEMP
36C
Temperature display in Centigrade for Power Supply circuit board NOTE:
that the PS temperature has dropped one degree
This display cycle repeats until the Display Mode Selector is pushed
DIAGNOSTIC MODE Power Supply Voltage Status (POWER)
DIAG/POWER
A quick push of the Display Mode Selector advances to the Power (POWR)
diagnostic sub-mode. Digital Display Characters are
Green
when
all
power
levels are normal and
Red
when
any
power level is outside normal level
DIAG/POWER
POWR
Indicates the display is in the POWER sub-mode
DIAG/POWER
BASE
Indicates that the Base Station main controller board is being measured
DIAG/POWER
POWER
Indicates the display is in the POWER sub-mode
DIAG/POWER
OK
Indicates that the item is in an OK State
DIAG/POWER
DISP
Indicates that the LED Display controller board is being measured
DIAG/POWER
POWER
Indicates the display is in the POWER sub-mode
DIAG/POWER
OK
Indicates that the item is in an OK State
DIAG/POWER
CHAR
Indicates that the Four Character controller board is being measured
DIAG/POWER
POWR
Indicates the display is in the POWER sub-mode
DIAG/POWER
OK
Indicates that the item is in an OK State
DIAG/POWER
AUD
Indicates that the Audio controller board is being measured
DIAG/POWER
POWR
Indicates the display is in the POWER sub-mode
DIAG/POWER
OK
Indicates that the item is in an OK State
DIAG/POWER
VBS
Indicates that the VBS (analog Video) controller board is being measured
DIAG/POWER
POWR
Indicates the display is in the POWER sub-mode
DIAG/POWER
OK
Indicates that the item is in an OK State
DIAG/POWER Exception
DIAG/POWER
ERR
Instead of OK, the display will show ERR if a power level is outside of
normal – ERR is followed by a Hexadecimal code. Please note the error
code and contact support at Telecast-Fiber.
Содержание CopperHead 3400