Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide –
Preliminary Version
Page 53
A
Belden
Brand
Connectors into and out of the Copperhead 3400 Base Station
13
VBS In
BNC Connector – Typically used to send SD return video to the camera – an example is monitor out
from the Production Switcher
14
SDI Out 1 & 2 (this carries the HD feed (not the 3D/Dual Link) from the camera)
BNC Connectors – Two identical video feeds from the camera – typically one may be used for local
HD monitoring and one is fed to the Production Switcher environment.
15
SDI In
BNC Connector – Typically used to send HD return video to the camera – an example is program out
from the Production Switcher
16
SDI Out A & B (this carries the dual 3D/Dual Link signals from the camera)
BNC Connectors
17
Audio In- Multi-Pin Connector
DB25 – 25 pin Connector follows the Tascam TDIF standard. The CopperHead 3400 Transceiver
System accommodates up to two Audio Channels at Line Level. This connector handles return audio
to the Camera location as well as intercom Program Audio. Please see Page 93 for sample wiring.
18
Audio Out- Multi-Pin Connector
DB25 – 25 pin Connector follows the Tascam TDIF standard. The CopperHead 3400 Transceiver
System accommodates up to two Audio Channels at Line Level. This connector handles Program
audio from the Camera location. Please see Page 94 for sample wiring.
19
&
20
Intercom Connectors #1 & #2
XLR 3 pin or 5 pin Connector depending on configuration. One of three options will be installed
(4-wire intercom, RTS or Clear-Com). Please see Chapter 6 – Section 6.4 for information on using each
of the Intercom Options
22
ST Fiber Connectors (used in place of connector 4)
Two ST Connector receptacles – Used as the Fiber Optic connection typically when infrastructure wire
or with one of the two external power supply option (MPS or HDX Power Adaptors)
23
12V Terminal Block
Terminal Block – bare wire connector. This can be used in place of the ADAP power connection in
installations that have 12V power distributed as part of their infrastructure. Do not use this at the same
time as the ADAP power connection.
24
Molex Power Connectors (used in place of 4 and only if so configured with ST Fiber Connectors)
5 Conductor Molex Connector – Used to provide power to the Hybrid Fiber Optic Cable. Typically
installed with infrastructure wiring with cable leading from Molex connector to a panel mounted
OpticalCON receptacle.