Telecast Fiber Systems – CopperHead 3400 Transceiver System User Guide –
Preliminary Version
Page 66
A
Belden
Brand
6.3.Powering the System
The CopperHead 3400 Base Station and the CopperHead 3400 Camera Unit each have a power up
routine which tests the equipment and performs a system diagnostic.
Powering the CopperHead 3400 Base Station
Base Station Main Power
1. Turn on the Base Station Power Mains Switch located at the rear left (when
facing the back of the Base Station) #3 on the overall diagram. This switch is
only on Base Station units with internal power. The front panel power light
will come on and be red until the next step.
Base Station Power
2. Turn on the Front Panel Power Switch located at the front right. #15 on the
overall diagram. The power monitor indicator turns from red to green.
Four Character Display
LED Indicator progression
3. The 4 character display indicates TEST and all front panel LEDs turn, red,
then green, then orange, then off.
REV display
4. The LED color test is followed by REV and the revision of the display
microcontroller firmware.
Scrolling
5. The REV indication is followed by “telecast-fiber.com” scrolling across the 4
character display. If there's no scrolling please contact Telecast Fiber
Systems support for assistance.
PAUSE
6. The scroll is followed by about a 3 second interval used to synchronize all
the microcontrollers in the Base Station
Diagnostics
7. The front panel will cycle through the diagnostics displays – See Section 6.5
– Page 71.
Current Status Displayed
8. After the 3 second pause, all the front panel displays update with current
status. If the Camera Unit is not powered on the camera related status
lights will show red.
Powering the CopperHead 3400 Camera Unit
Camera Unit power
1. Turn on the Camera Unit Power Switch
Camera Power
2. Turn on the Camera Power and also any peripheral equipment connected to
the camera or the CopperHead 3400 Camera Unit such as monitors and
microphones.
Four Character Display
LED Indicator progression
3. On power on the four character display indicates the current Revision
Version (REVA). Your unit will reflect the current Revision Version. After the
revision display the current Fiber Link strength is displayed. A typical display
is -8 to -13. This indicates Fiber link strength of from -8 to -13 dBm.
Both the Camera Unit and the Base Station have a digital display selector button which allows multiple
functions for the digital display. These functions are described below on Page 70.
Содержание CopperHead 3400
Страница 2: ......