![TelcoBridges TSBC Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/telcobridges/tsbc-series/tsbc-series_installation-manuals_1079425034.webp)
TSBC Series System Installation Guide
28
4.3
Grounding the Equipment Chassis
As a standard safety practice, the chassis of the TSBC-HW-TRANS must be properly grounded to
protect against any contact with an electrical fault condition. It is recommended that the chassis be
connected to earth ground. When the TSBC-HW-TRANS is installed in an equipment rack, connect the
ground wire between the ground lug of the Transcoding unit and the equipment rack ground bar.
Guidelines
•
Use 10 AWG (minimum) stranded ground wire.
•
Terminate equipment side of ground wire with a #10 ring terminal.
•
Keep the length of the ground wire as short as possible.
•
Do NOT daisy chain the ground between equipment. Use a ground bus bar, as show in
Figure
4.3
on page
28.
•
Do not over tighten ground lug connections.
To connect the TSBC-HW-TRANS to ground:
1.
Connect one end of a ground wire to the ground lug of the TSBC-HW-TRANS. See Figure
4.3
on
page
28.
2.
Connect the other end of the ground wire to a ground bar of the equipment rack. If the TSBC-HW-
TRANS is not installed in an equipment rack, connect the ground wire to earth ground.
3.
Verify that the resistance of the ground path is less than 0.5 ohms.
Figure
4.3
Chassis Ground Connection
MGMT0
ETH
VOIP
0
1
0
1
TMS
0
1
Ground Bar
MGMT0
ETH
VOIP
0
1
0
1
TMS
0
1
Earth
Ground
DC Unit
Earth
Ground
AC Unit
(or)
Содержание TSBC Series
Страница 1: ...TSBC Series Installation Guide TSBC HW August 1 2017...
Страница 20: ...TSBC Series System Installation Guide 14...
Страница 29: ...23 Installing the TSBC HW SRV Figure 3 8 TSBC HW SRV DC Power Connections DC Power Source 1 DC Power Source 2...
Страница 30: ...TSBC Series System Installation Guide 24...
Страница 40: ...TSBC Series System Installation Guide 34...
Страница 42: ...TSBC Series System Installation Guide 36...