Specifications
TLA600 Series Logic Analyzer Service Manual
1- 15
Table 1- 17: Certifications and compliances (Cont.)
Category
Standards or description
EC Declaration of Conformity --
Low Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the
European Communities:
g
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC
EN 61010-1/A2:1995
Safety requirements for electrical equipment for measurement
control and laboratory use.
EN 61010-2-031:1994
Particular requirements for hand-held probe assemblies for
electrical measurement and test equipment.
EN 61010-2-032:1995
Particular requirements for hand-held current clamps for electrical
measurement and test equipment.
Canadian Certification
CAN/CSA C22.2 No. 1010.1
Safety requirements for electrical equipment for measurement,
control, and laboratory use.
Installation (Overvoltage)
Category
Terminals on this product may have different installation (overvoltage) category designations. The
installation categories are:
g y
CAT III
Distribution-level mains (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.
CAT II
Local-level mains (wall sockets). Equipment at this level includes appliances, portable
tools, and similar products. Equipment is usually cord-connected.
CAT I
Secondary (signal level) or battery operated circuits of electronic equipment.
Pollution Degree
A measure of the contaminates that could occur in the environment around and within a product.
Typically the internal environment inside a product is considered to be the same as the external.
Products should be used only in the environment for which they are rated.
Pollution Degree 2
Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivity that is caused by condensation must be
expected. This location is a typical office/home environment.
Temporary condensation occurs only when the product is out of
service.
Safety Certification Compliance
Equipment Type
Test and measuring
Safety Class
Class 1 (as defined in IEC 1010-1, Annex H) -- grounded product
Overvoltage Category
Overvoltage Category II (as defined in IEC 1010-1, Annex J)
Pollution Degree
Pollution Degree 2 (as defined in IEC 1010-1). Note: Rated for indoor use only.
Содержание TLA600 Series
Страница 5: ......
Страница 13: ...Table of Contents viii TLA600 Series Logic Analyzer Service Manual...
Страница 17: ...Service Safety Summary xii TLA600 Series Logic Analyzer Service Manual...
Страница 51: ...Theory of Operation 3 4 TLA600 Series Logic Analyzer Service Manual...
Страница 89: ......
Страница 97: ...TLA600 Adjustment Procedures 5 8 TLA600 Series Logic Analyzer Service Manual...
Страница 113: ...Maintenance 6 4 TLA600 Series Logic Analyzer Service Manual...
Страница 157: ...Repackaging Instructions 6 48 TLA600 Series Logic Analyzer Service Manual...
Страница 159: ...Options 7 2 TLA600 Series Logic Analyzer Service Manual...
Страница 161: ...Electrical Parts List 8 2 TLA600 Series Logic Analyzer Service Manual...
Страница 165: ...Diagrams 9 4 TLA600 Series Logic Analyzer Service Manual...
Страница 176: ...Mechanical Parts List TLA600 Series Logic Analyzer Service Manual 10 11...
Страница 185: ...Mechanical Parts List 10 20 TLA600 Series Logic Analyzer Service Manual...
Страница 186: ......
Страница 187: ......