Reference
RFA300A Measurement Set 8VSB
3- 17
The other sync signal added to the multiplexer is the Frame synchronizing
segment. As shown in Figure 3--17, a transmission data frame is 616 segments
(48.4 ms) long. A Frame sync segment is sent every 313 segments (24.2 ms).
The Frame sync segment carries the training reference signals for the receiver
equalizer. It consists of the following:
H
Four byte segment sync.
H
Five hundred and eleven reference symbols that the receiver uses for
adjusting long equalizer taps.
H
Three sets of 63 reference symbols for short equalization.
H
Twenty-four symbols for VSB level ID.
H
Ninety-two reserved symbols.
H
Twelve symbols repeated from the previous segment.
Frame Sync #2
Frame Sync #1
828 Symbols
313 Segments
(24.2 ms)
1 Segment =
832 Symbols =
77.3
s
313 Segments
(24.2 ms)
4
Figure 3- 17: Frame synchronizing segment