Appendix A: Specifications
RFA300A Measurement Set 8VSB
A- 17
Table A- 10: Certifications and compliances (Cont.)
Category
Standards or description
Installation (Overvoltage)
Category
Terminals on this product may have different installation (overvoltage) category designations. The
installation categories are:
CAT III
Distribution-level mains (usually permanently connected). Equipment at this level is
typically in a fixed industrial location.
CAT II
Local-level mains (wall sockets). Equipment at this level includes appliances, portable
tools, and similar products. Equipment is usually cord-connected.
CAT I
Secondary (signal level) or battery operated circuits of electronic equipment.
Pollution Degree
A measure of the contaminates that could occur in the environment around and within a product.
Typically the internal environment inside a product is considered to be the same as the external.
Products should be used only in the environment for which they are rated.
Pollution Degree 1
No pollution or only dry, nonconductive pollution occurs. Products in this
category are generally encapsulated, hermetically sealed, or located in
clean rooms.
Pollution Degree 2
Normally only dry, nonconductive pollution occurs. Occasionally a
temporary conductivity caused by condensation must be expected. This
location is a typical office/home environment. Temporary condensation
occurs only when the product is out of service.
Pollution Degree 3
Conductive pollution, or dry, nonconductive pollution that becomes
conductive due to condensation. These are sheltered locations where
neither temperature nor humidity is controlled. The area is protected from
direct sunshine, rain, or direct wind.
Laser Classification
This product contains a CD ROM drive which utilizes a Class 1 laser and complies with
EN60825--1:94 and with the U.S. FDA regulations. The drive is marked with the laser’s
classification and date of manufacture, as well as the following information: Complies with the
DHHS rules 21 CFR Chapter 1, Subchapter J applicable at the date of manufacture.
Safety standards
Safety Certification Compliance
Temperature, operating
+5 to +50
_
C
Altitude (maximum
operating)
3000 meters
Equipment Type
Test and measuring
Safety Class
Class 1 (as defined in IEC 1010-1, Annex H) -- grounded product
Installation (Overvoltage)
Category
Overvoltage Category II (as defined in IEC 1010-1, Annex J)
Pollution Degree
Pollution Degree 2 (as defined in IEC 1010-1). Note: Rated for indoor use only.
Supply Voltage Range
100 -- 240 VAC 50/60 Hz, single phase
Current Rating
6.0 Amps max
Fuse Rating
Mains fuse is 10A, 250V, Fast; Not operator replaceable. Refer servicing to qualified service
personnel.
Relative Humidity
(maximum operating)
80 % for temperatures up to 31
°
C, decreasing linearly to 50 % at 40
°
C
Содержание RFA300A
Страница 1: ...User Manual RFA300A Measurement Set 8VSB 071 0697 01 www tektronix com...
Страница 4: ......
Страница 10: ...Table of Contents vi RFA300A Measurement Set 8VSB...
Страница 102: ...Appendix C System Recovery C 12 RFA300A Measurement Set 8VSB...
Страница 108: ...Glossary Glossary 4 RFA300A Measurement Set 8VSB...
Страница 112: ...Index Index 4 RFA300A Measurement Set 8VSB...