Command Groups
3–14
VX1410 IntelliFrame Instruction Manual
Table 3–8: Status Commands (Cont.)
Header
Description
Returns the time when the ACFAIL signal was asserted.
Queries the VXI Bus Error address space.
Sets or queries the contents of the VXI Monitor Enable
register.
Returns the time when the VXI SYSFAIL signal was
asserted.
%
Presets the SCPI enable registers, transition filters,and
the Error/Event queue enable.
%#"
Returns the contents of the Questionable Register as a
decimal number.
$
Returns the contents of the Blower Event register.
%#"
Returns the contents of the Blower Condition register.
Sets or queries the contents of the Blower Enable
register.
Returns the fan speed in revolutions per minute.
%#"
Returns the contents of the Questionable Condition
register.
Sets or queries the contents of the Questionable Status
Enable register.
$
$'
Sets or queries the filter cleaning interval time.
""
Returns the remaining time for the next filter cleaning
cycle.
%
Resets the remaining filter cleaning time to the filter
cleaning interval.
$%&$
Returns the contents of the Temperature Event register
as a decimal number.
!&!
Returns the maximum measurable temperatures in the
mainframe since power on.
%#"
Returns the contents of the Temperature Condition
register.
Sets or queries the contents of the Temperature Enable
register.
Returns the current temperatures in the mainframe.
%
Sets or queries the maximum ambient and delta
temperatures in each slot of the mainframe.
!&!
Returns the maximum measurable temperatures in the
mainframe since the last factory maintenance.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com