Getting Started
1–8
VX1410 IntelliFrame Instruction Manual
trays following the procedures in this section. Both options come with butch
plates to mount cable connectors at the rear of the cable trays.
Both cable tray options can be installed three different ways as shown in the
following illustrations. In each example, place the mainframe upside-down or on
one of the sides on a clean working surface and follow the instructions in the
illustrations. To install the cable trays you need a T-15 and a T-20 Torx Driver.
Figure 1–2 on page 1–9 shows how to install Option 1U to provide a cable tray
depth of 1.75 inches. Similarly, you can install Option 2U to provide a cable tray
depth of 3.5 inches.
Figure 1–3 on page 1–10 shows how to install Option 2U to provide a cable tray
depth of 4.25. Similarly, you can install Option 1U to provide a cable tray depth
of 2.5 inches.
Figure 1–4 on page 1–11 shows how to install Option 2U to provide a cable tray
depth of 6.0 inches. Similarly, you can install Option 1U to provide a cable tray
depth of 4.25 inches.
You can modify the butch plate to accept cable connectors at the rear of the
mainframe. Specific instructions for modifying the butch plate are not given
since the locations, types, and size of connectors vary with each application.