Display a Waveform
Search
Description
Runt
Searches for positive or negative pulses that cross one amplitude threshold but fail to cross
a second threshold before crossing the first again. Search for all runt pulses or only those
with a duration >, <, =, or
≠
a user-specified time.
Window
Searches for a signal that is entering or leaving the threshold window. Qualify the search
in terms of time by using the When Wider option, or by the logical state of other channels
using the When Logic option.
Pattern
Search for a logic pattern (AND, OR, NAND, or NOR) across multiple waveforms with each
input set to either High, Low, or Don’t Care. Search for when the event goes true, goes
false, or stays valid for >, <, =, or
≠
a user-specified time. Additionally, you must define one
of the inputs as a clock for synchronous (state) searches.
Transition
Search for rising and/or falling edges that are >, <, =, or
≠
a user-specified time.
Timeout
Searches for no pulse in a specified time.
State
Searches for when all of the logic inputs to the selected logic function cause the function to
be True or False when the clock input changes state.
DDR Read
Searches for DDR read pulses. Requires option DDRA.
DDR Write
Searches for DDR write pulses. Requires option DDRA.
DDR Read and Write
Searches for DDR read and write pulses. Requires option DDRA.
112
MSO70000/C, DPO/DSA70000B/C, DPO7000, and MSO/DPO5000 Series User Manual
Содержание DPO7054
Страница 3: ......
Страница 7: ......
Страница 206: ...Appendix Connecting the Probe to the Circuit MSO70000 C DPO DSA70000B C DPO7000 and MSO DPO5000 Series User Manual 185 ...
Страница 207: ...Appendix 186 MSO70000 C DPO DSA70000B C DPO7000 and MSO DPO5000 Series User Manual ...
Страница 212: ......
Страница 213: ......