Adjustment Procedure
7–8
1710J-Series Waveform Monitors
2. Use a 75
W
coaxial cable to connect the multiburst output from the television
test signal generator to one side of the CH A input loop-through. See
Figure 7–4.
3. Use a 75
W
coaxial cable to connect the digital counter to the remaining side
of the input loop through connector.
1710J-Series Waveform Monitor
Television Test Signal Generator
Multiburst signal
Digital
Counter
Figure 7–4: Equipment setup to adjust 0.2
m
s timing
4. Set the multiburst generator to low, continuous, and manual. Turn markers
off.
5. Adjust the multiburst Frequency for a 5 MHz sine wave as measured on the
digital counter.
6. Change the multiburst generator to Composite.
7. Select 1 LINE sweep and turn on the MAG.
8. Adjust R553 for 10 cycles of subcarrier over 10 divisions
±
1 minor division.
Recheck multiburst generator frequency by switching it back to Continuous.
9. Disconnect the cable that goes to the digital counter and terminate the open
side of the CH A input with a 75
W
end-line terminator.
The component to adjust is A1R003.
1. Select 2 LINE sweep and turn the MAG off.
2. Hold the waveform monitor FILTER button in until both the FLAT and
LPASS indicators light.
Dual Filter Switching
Содержание 1710J Series
Страница 4: ......
Страница 14: ...Table of Contents x 1710J Series Waveform Monitors ...
Страница 18: ...Service Safety Summary xiv 1710J Series Waveform Monitors ...
Страница 22: ...Preface xviii 1710J Series Waveform Monitors ...
Страница 23: ...Getting Started ...
Страница 24: ......
Страница 45: ...Operating Basics ...
Страница 46: ......
Страница 55: ...Reference ...
Страница 56: ......
Страница 64: ...Reference 3 8 1710J Series Waveform Monitors ...
Страница 65: ...Specifications ...
Страница 66: ......
Страница 74: ...Specifications 4 8 1710J Series Waveform Monitors ...
Страница 76: ......
Страница 77: ...Theory of Operation ...
Страница 78: ......
Страница 100: ...Theory of Operation 5 22 1710J Series Waveform Monitors ...
Страница 101: ...Performance Verification ...
Страница 102: ......
Страница 120: ...Performance Verification 6 18 1710J Series Waveform Monitors ...
Страница 121: ...Adjustment Procedure ...
Страница 122: ......
Страница 138: ...Adjustment Procedure 7 16 1710J Series Waveform Monitors ...
Страница 139: ...Maintenance ...
Страница 140: ......
Страница 168: ...Maintenance 8 28 1710J Series Waveform Monitors Figure 8 11 Repackaging a 1710J Series Waveform Monitor ...
Страница 169: ...Replaceable Electrical Parts ...
Страница 170: ......
Страница 204: ...Replaceable Electrical Parts 9 34 1710J Series Waveform Monitors ...
Страница 205: ...Diagrams ...
Страница 206: ......
Страница 226: ......
Страница 227: ...Replaceable Mechanical Parts ...
Страница 228: ......
Страница 239: ...Replaceable Mechanical Parts 1710J Series Waveform Monitors 11 11 1 2 3 4 5 6 Figure 11 4 Accessories ...
Страница 240: ...Replaceable Mechanical Parts 11 12 1710J Series Waveform Monitors ...
Страница 244: ...Glossary Glossary 4 1710J Series Waveform Monitors ...
Страница 251: ......
Страница 252: ......