background image

 

20 

Examples

 of screens:

 

 

 
 

 

or

 

 

 

Upon cancellation of filtration in the menu item 

«

4.Failures

» you may select the last 

item 

«

5.All

», which will activate a general list of failures, which may be browsed by 

pressing 

▼, ▲. 

 

7.3.4

   

The  present  FW  version  is  not  restricted  by  authorizations  for  viewing  the 

event log.  
The  menu  item «

5.Event  log

»  enables  viewing events  stored  in  CP  memory  using 

filters: 
«

1.Failures

»  

 

 

– critical failures. 

«

2.Alarms

»  

 

–  only  «alarms»  /  «fires»  /  «violations»  in  the  armed 
partitions. 

«

3.W/o arm/disarm

»  

–  all  the  events  in  all  categories  except  “arming”  and 

“disarming”. 

«

4. By part. number

»          – all the events in the selected partition. 

«

5.All

» 

 

–  all  the  events  in  the  system  without  filters,  including 

information about activities of 

Engineer

  

 

When any of the filters is chosen, the keypad addresses CP with an inquiry according 
to the type of the chosen filter and adds last 

10 events

 selected using the filter to the 

temporary storage buffer. Inquiry to CP is similar to described in 

6.2.2.

 

 
When the filter «

1.Failures

» is selected, the information is displayed from the last in 

time  event  (having  the  largest  number  in  the  current  working  cycle  of  CP  from 
10000).  

Example

 of screen:

 

 
 
 

 

Here in the example:  
«

Event 2181

» – event number  (from 10000). 

«

Failure

»  

– interpretation of event. 

«

system

»  

– involved area. 

 

IP  0004    
BPS low voltage

 

 

 

 

MC  0034    
No connection 

 

 

 

Event 2181     Failure    
                       system 

 

 

 

Содержание Atra-814 Pro

Страница 1: ...Research and Development Center TEKO CONTROL KEYPAD Operation Manual...

Страница 2: ...9 6 1 Control 9 6 2 Informational Capacity 10 7 Keypad Menu 13 7 1 Menu Structure 13 7 2 User Menu 14 7 3 Operator Menu 18 7 4 Technician Menu 22 7 5 Engineer Menu 28 8 Pre Starting Procedure Registra...

Страница 3: ...l current condition of system partitions connected to the panel RM Relay Module Astra RM Monitor Program module from MSS Astra Pro Setup module Program module from MSS Astra Pro NC Normally closed NO...

Страница 4: ...tor Module Astra PSTN RELAY Relay output UART RS 485 LIN Types of hardwired digital communication interfaces BAT Accumulator battery 1 Application 1 1 The keypad is designed to be included into stra Z...

Страница 5: ...ent consumption m max 150 Characteristics of AL1 AL2 terminals Zone1 GND Zone2 Voltage across terminals of AL in standby mode V 10 27 Short circuit current across AL m max 20 Alarm loop resistance in...

Страница 6: ...pad Astra 814 Pro 1 pc Screw 3 9 32 4 pcs Dowel 6 30 4 pcs Resistor 1 4 0 25 W 3 9 kOhm 5 2 pcs Operation Manual 1 pc 4 Structure 4 1 The keypad consists of a base a keyboard with a closing cover a di...

Страница 7: ...inal block see application in Table 1 Table 1 Terminals Application LIN Not applicable Relay1 System relay output operation mode is set by MSS Astra Pro U1 GND Connection of main power source input U2...

Страница 8: ...to return the main part of notification on the display 0 9 Enter PIN codes and other digital values PIN Authorization or entering the Engineer Technician Operator User menu according to access level...

Страница 9: ...sion is open in the System Core and operation of the Monitors is suspended After running time of active Engineer mode expires the keypad sends a command for automatic termination of Engineer session i...

Страница 10: ...o the following priorities with status is displayed 1 Fire 7 Exit delay 2 Fire danger 8 Sabotage 3 Alarm 9 Critical failure 4 Violation 10 Service required 5 Test 11 Standby mode 6 Entry delay To view...

Страница 11: ...Indicators of consolidated signals show generalized current status of system partitions corresponding to specific indicators on the keypad Table 2 Assigning a partition to a specific indicator is don...

Страница 12: ...dy Blinking green light 1 time per 2 s Normal Constant green light Fire danger Blinking red light 1 time s FIRE Not applicable Not lit Not ready Blinking green light 1 time in 2 s Normal Constant gree...

Страница 13: ...neer menu 1 Part status 1 Part control 1 Part control 1 Sys dev status 1 View all 2 Alert control 2 Alert control 2 Wls dev status 2 By part number 1 Start alerting 1 Start alerting 3 Part status 2 Pa...

Страница 14: ...ontrast 2 est 2 Key volume 1 Test Keybd 3 Act mode time 2 Test backlight 4 Backlight 3 Test BZ 2 FW version 4 Status test 3 FW update 3 FW version 9 Date setting 4 FW update 10 Time setting 7 Date set...

Страница 15: ...alarm status D partition is in Fire danger status S partition is in sabotage status 7 2 3 After entering menu sub item 2 By part number the display will show partition number and information about th...

Страница 16: ...evice detection channel in the given example built in magnet steered contact 007 partition number alarm event type In case the partition is not ready to be armed you should eliminate causes In excepti...

Страница 17: ...ypass are executed the partition which is not ready to be armed will be armed with the following notification After the notification appears by pressing you may see detailed conditions of arming as vi...

Страница 18: ...ll be built depending upon authorizations established for the PIN code which has been entered Examples of screens press press press select an option and press Areas are selected from a list which may...

Страница 19: ...red when you set up time of delay 7 3 3 The menu item 4 Failures enables to view failures using filters for your convenience 1 By part number failures service required and sabotage 2 Sabotage tamperin...

Страница 20: ...er all the events in the selected partition 5 All all the events in the system without filters including information about activities of Engineer When any of the filters is chosen the keypad addresses...

Страница 21: ...f screen Here in the example No connect event MC0034 type of the device and ES address 0034 number in the list of radio units 23 rd Jan date of event according to calendar of CP 11 51 11 a m time of e...

Страница 22: ...CP and the keypad uses the following entitlements RTR Astra Z 8745 versions A B Repeater Router Astra Z 8845 versions A B Repeater Router Zone GND PIR Astra Z 5145 versions A B P PIR motion detectors...

Страница 23: ...NC Key pressed on KF and on WKP For KF and WKP ALM Violation in the main detection channel For RTR 8845 PIR AC MC TRZ WLD VBR WRU FR Violation in the main detection channel For FSD FHD FCP FLR wireles...

Страница 24: ...interfaces UART RS 485 LIN In the present FW version for CP CP Central Control Panel Astra 8945 Pro HKP Keypad Astra 814 Pro RVZ Embedded wireless receiver WE Wireless extender Astra Z WE HE Hardwire...

Страница 25: ...tialized there will appear the notification Initialization For different types of devices the 2 nd and 3 rd items may display various types of information For RU in the 2nd pos for Output1 NOR control...

Страница 26: ...egrated into Setup Module of MSS Astra Pro software D AL resistance within 1 5 to 3 0 kOhm For AL of fire combined double event type means that only one detector is in fire status For AL of fire heat...

Страница 27: ...to SIM card required 6 unlocking of SIM card required 7 no GSM service 8 search network 9 registration of network rejected 7 4 4 The item menu 8 HKP allows to change the display contrast the volume of...

Страница 28: ...4 5 You may change FW without preliminary registration in CP It is possible as well to adjust display contrast duration of active mode and the volume of sound of pressed keys 7 5 2 After the keypad ha...

Страница 29: ...stering in wireless network 1 Test keyboard after pressing the following view screen will appear where each pressing of keys on the keyboard will result in darkening in the example keys 1 2 3 4 5 are...

Страница 30: ...for intrusion type AL status NOR AL2 terminal Zone2 normal ALM AL2 terminal Zone2 violated In the 4th position for main and backup power sources NOR both power supply sources are normal AL1 ZONE1 nor...

Страница 31: ...nd remove the cover 3 Insert wires through the hole in the bottom base and connect them following the scheme Where Rter terminal resistor in the alarm loop 3 9 kOhm E1 power supply unit operability ou...

Страница 32: ...1 2 3 4 5 6 Test the keypad following instructions from 2 est sub item of the 6 HKP menu item see 7 5 6 6 Replace the cover of the terminal block section and tighten the screws If necessary close the...

Страница 33: ...rews 8 If necessary close the cover of the keyboard 9 Maintenance To ensure fault free operation of the keypad it is recommended to test it and perform technical maintenance as follows check operabili...

Страница 34: ...ce with GOST ISO 9001 13 2 The manufacturer guarantees that the keypad will comply to technical requirements provided that the consumers adhere to specified technical conditions of transportation reco...

Страница 35: ...35 MOUNTING LAYOUT...

Страница 36: ...1 33 47051 Duisburg Germany Phone 49 0 203 393 91 188 Fax 49 0 203 393 91 189 GSM 49 0 178 218 48 22 E mail info controlex eu Web www controlex eu Prospekt Pobedy str 19 420138 Kazan Russia Phone 7 84...