background image

THE KEYPAD

MODE

There are 3 modes:-

Defrost: 

The LED will be illuminated whilst the machine is busy  

 

 

 

defrosting (normally in very cold, winter conditions).

Heat:   

The LED will be illuminated when the machine is set for    

 

 

heating the water.

Cool:   

The LED will be illuminated when the machine is set for    

 

 

cooling the water.

1

ON / OFF switch

(OFF  =  STANDBY;  ON  =  RUNNING)

In the “OFF” position the display shows the time, i.e. 12.34.
In the “ON” position the display shows current pool temperature, i.e. 22.0.

It is important to remember that whilst the machine is in the “ON” position, 
i.e. showing temperature, you can only view the settings.

In order to change the settings the machine must be in the “OFF” position, 
i.e. showing time.

The rate of heating the water will be the same, it does not matter what the 
required set temperature is, i.e. by setting the temperature very high, this 
won’t increase the rate of heating.

By setting the required temperature too high, this will only cause a higher 
electricity consumption and not a quicker heating time.

HOW TO SET THE REQUIRED TEMPERATURE

1. 

Set the machine to “OFF/STANDBY” (the LED will show time).

2. 

Press    or    to Parameter 1.

3. 

Quick press and release the “MODE” and “ON/OFF”  

 

 

 

simultaneously.

4. 

The current set temperature will flash.

5. 

Use the     or    to set the required temperature.

6. 

Wait until the LED returns to time.

7. 

Switch the machine “ON”.

2

Содержание Keypad

Страница 1: ...ature you can only view the settings In order to change the settings the machine must be in the OFF position i e showing time The rate of heating the water will be the same it does not matter what the required set temperature is i e by setting the temperature very high this won t increase the rate of heating By setting the required temperature too high this will only cause a higher electricity con...

Страница 2: ... will flash Use the or to set the required minutes Once the minutes have been set press TIMER ON again to save the time setting 3 How to Set The Timer OFF time when machine need to run in 24 hour cycle Whilst the machine is in the OFF position i e showing time press TIMER OFF twice The first two digits on the LED screen will flash Use the or to set the required hours Press TIMER OFF again The last...

Страница 3: ...To set the inlet water temperature when in cooling mode 8 28 C Default setting 27 C Parameter 3 Defrost starting temperature Defrosting function 30 0 C Default setting 6 C 5 Parameter 9 Pump 0 always open 1 10 sec start before compressor starts 30 sec stop after compressor stops Inlet water temperature HOW TO SET THE PARAMETERS The machine must be in the OFF position Press or to scroll until you r...

Страница 4: ... Coil 2 sensor failure D The sensor is open or short circuit Check or change the sensor PP5 Ambient temperature sensor failure E The sensor is open or short circuit Check or change the sensor PP6 Temp differential between water in and water out is too high Water flow volume too low water pressure difference is too low Check the water flow volume pressure PP7 Machine in defrost mode Ambient or inle...

Страница 5: ... blanket you will not be able to maintain a constant temperature in your swimming pool A good example to think of is driving your car with the air conditioning on and all the windows down WHY IS THERE WATER DRIPPING FROM UNDER THE HEAT PUMP When the heat pump is running in the heating mode condensation build up on the evaporating coils will cause water dripping under the heat pump This is a normal...

Отзывы: