31
8 Pre-Starting Procedure. Registration and
Installation
After being transported in conditions which differ from operating ones, the keypad
must be left unpacked under operating temperature for minimum 4 hours.
8.1 Wiring
1.
Open the keyboard cover.
2.
Loosen two screws on the terminal block section with a
screwdriver, and remove the cover.
3.
Insert wires through the hole in the bottom base and
connect them following the
scheme
:
Where:
Rter
– terminal resistor in the alarm
loop 3,9 kOhm;
E1
– power supply unit operability
output with NC contacts;
E2
- power supply unit operability
output with NO contacts;
E3
- intrusion detector with NC
contacts;
E4
- intrusion detector with NO
contacts;
PS1
– main power supply unit;
PS2
– backup power supply unit;
К1
– reader Touch memory or other
technology issuing Dallas 1990A
code.
Astra-814 Pro
CSP
PS1
PS2
Rt
er
Rt
e
r