GB / IE - 3
5410.265.04
Part 2
Transformation and adaptation
To convert the appliance to another type of gas, e.g. from natural gas to
LPG, the nozzles of the main burner, by-pass and pilot light have to be
changed. All the nozzles are marked with a number that indicates the
diameter in 1/100 of a mm and are supplied in a bag.
After each conversion or adaptation, the unit must undergo an operating
test and the supplementary plate must be updated according to the
conversion or adaptation carried out.
Connection to the distribution network, installation, and maintenance of the appliance must only be carried out by qualified technicians
only, in observance of all applicable regulations!
Cooktop burner, nozzles and air adjustment
BURNER:
1.
Pull the knobs off (fig.3).
2.
Remove the control panel by unscrewing the fixing screws at the
rear.
3.
Replace nozzle "U" (fig.9) with a suitable one for the new type of
gas indicated in the "MAX" nozzles table T1 section
Specifications.
ADJUSTING THE AIR:
4.
Loosen fixing screw "X" (fig.9)
5.
Adjust the primary air by moving the bush a distance “H” indicated
in nozzles table T1section Specifications.
6.
Screw the fixing screws in.
PILOT LIGHT:
7.
Unscrew and remove the closing nut.
8.
Unscrew and replace the pilot nozzle “D” (fig.9.12) with a suitable
one for the new type of gas indicated in the nozzles table T1
section Specifications.
9.
Replace and tighten the closing nut.
MINIMUM:
10.
Unscrew and replace or adjust the minimum by-pass nozzle "Um"
(fig.11) on the basis of the indications in the nozzles table T1
section Specifications.
11.
Remove the control panel.
12.
Replace the knob.
Oven burner (models GG7)
To replace the nozzle of the oven burner, the pilot light and adjust the
primary air, follow the instructions below:
BURNER:
1.
Remove the base of the oven "H" (fig.13)
Unscrew and replace the nozzle with a suitable one for the new type
of gas indicated in the "MAX" nozzles table T1 section
Specifications.
ADJUSTING THE AIR:
2.
Loosen fixing screw "X" (fig.12)
3.
Adjust the primary air mount the bush a distance “H” indicated in
nozzles table T1 section Specifications (see fig.14).
4.
Block the bush, by screwing in fixing screw “X” (fig.12).
G30 - H=7mm
G20 - G25 CLOSED
PILOT LIGHT:
5.
Unscrew and remove closing nut "Z" (fig.12)
6.
Unscrew and replace pilot nozzle “D” (fig.9.12) with a suitable one
for the new type of gas indicated in the nozzles table T1 section
Specifications.
7.
Replace and tighten closing nut "Z" (fig.12)
8.
Replace the base of the oven "H" (fig.12)
MINIMUM:
9.
Pull the knobs off.
10.
Remove the control panel by unscrewing the fixing screws at the
rear.
11.
Unscrew and replace or adjust the minimum by-pass nozzle "Um"
(fig.11) on the basis of the indications in the nozzles table T1
section Specifications.
12.
Remove the control panel.
13.
Replace the knob.
N.B. If the bottom of the oven chamber is removed, it must be put back
in exactly the same position.
Содержание PF105G7
Страница 42: ...DISEGNI DIAGRAMS A 5410 265 04 ...
Страница 43: ...DISEGNI DIAGRAMS B 5410 265 04 ...
Страница 44: ...DISEGNI DIAGRAMS C 5410 265 04 ...
Страница 45: ...DISEGNI DIAGRAMS D 5410 265 04 ...
Страница 46: ...DISEGNI DIAGRAMS E 5410 265 04 ...
Страница 47: ...DISEGNI DIAGRAMS F 5410 265 04 ...
Страница 49: ...DISEGNI DIAGRAMS H 5410 265 04 ...
Страница 50: ...DISEGNI DIAGRAMS I 5410 265 04 ...