GB / IE - 2
5410.265.04
Evacuation of burnt gases
This equipment doesn't need to be connected to a flue, but we do recommend installing it under an extractor hood.
Checking the pressure
The distribution network pressure must meet the following specifications:
LPG
ALLOWED
From 20/25 to 35/45mbar
NOT ALLOWED
Below 20/25 above 35/40mbar
METHANE- H
ALLOWED
From 17 to 25mbar
NOT ALLOWED
Below 17 above 25mbar
If the gas distribution network pressure on the installation site doesn't
meet the above values, inform the gas board and do not turn the unit on
until the cause and a solution have been found.
The distribution network pressure can be taken with a U manometer
(min. definition 0.1 mbar), connected to the pressure outlet behind
control panel “H” (fig.11).
1.
Remove the control panel.
2.
Remove the screw and sealing washer (fig.11) from the pressure
outlet and connect the manometer.
3.
Turn the unit on following the enclosed instructions and check that
the pressure is within the permitted pressure range.
4.
Disconnect the manometer and replace the screw and the sealing
washer in the pressure outlet.
5.
Replace the control panel.
Electrical connection (models G7)
Before proceeding with the electrical connection, check the specifications
on the data plate. The appliance is not supplied with a power cable.
The installer must make the connection after having installed a main
switch, which, as well as being easy to reach, must disconnect all of the
contacts supplying electrical energy to the appliance with a minimum
distance of at least 3mm between the poles.
The power cable must meet the minimum standards of H07 RN-F and
have a minimum section of 5x1.5 mm
2
; it must not be installed near heat
sources and the temperature of the place in which the appliance is
installed must not rise above 50°C. To reach terminal board “M” (fig.10)
remove panel "H" on the front of the appliance. Following the indications
in the wiring diagram, connect the wires of the power cable to the
terminal board. The appliance must be connected to a good earth. For
this purpose you will find the earth terminal on the terminal board,
identified with the “ ” symbol and to which the earth wire must be
connected. Slide the cable near to the terminal board, hold the cable in
place until you can block it with cable clamp “ ” (fig.1).
The appliance must also be connected to an equipotential earth. This
connection can be made using the equipotential terminal marked with the
symbol “ ”, placed under the appliance near the right rear foot.
The equipotential wire must have a section of 10mm
2
.
Содержание PF105G7
Страница 42: ...DISEGNI DIAGRAMS A 5410 265 04 ...
Страница 43: ...DISEGNI DIAGRAMS B 5410 265 04 ...
Страница 44: ...DISEGNI DIAGRAMS C 5410 265 04 ...
Страница 45: ...DISEGNI DIAGRAMS D 5410 265 04 ...
Страница 46: ...DISEGNI DIAGRAMS E 5410 265 04 ...
Страница 47: ...DISEGNI DIAGRAMS F 5410 265 04 ...
Страница 49: ...DISEGNI DIAGRAMS H 5410 265 04 ...
Страница 50: ...DISEGNI DIAGRAMS I 5410 265 04 ...