TP8-96 VIDEO
- Installer Manual
Zone configuration
2-3
PROGRAMMING OF A TRADITIONAL DETECTOR
Traditional detector.
The definition of traditional detector indicates all types of conventional detectors which signal an
alarm by simply switching a contact. They include detectors with relay output, magnetic contacts, inertia detectors,
rope contacts etc.
The first part of programming is identical to any other category of detectors.
Select the
Module
(1 to 15) and a standard loop wiring among the options available.
ZONES CONFIGURATION
z
Type of zone
Select from the drop-down menu, the zone type among the following options:
• Excluded
The zone is permanently disabled for the detection of alarms.
• Direct zone
The zone is enabled for the detection of alarms immediately after arming of the program it is included in without
taking into account any entry or exit time (the zone is ready after 20 seconds).
• Walk through
The zone is a mixed zone. It is normally direct and enabled upon arming, but behaves as a delayed zone if
another delayed zone is in prealarm (entry time running) or during the exit time. It is used if one detector covers
more than one zone, e.g. entrance and hall, situated along the entry/exit path in which the walk through zone is
the more distant one.
• Technical
The zone is always enabled (even if the control panel is disarmed). It is used for the detection of gas leaks, fire
alarms or as expansion to the tamper line.
• Delayed T1 (exit time 1)
The zone is not enabled for the detection of alarms upon arming of the program it is included in but only after
expiry of the programmed exit time 1.
• Delayed T2 (exit time 2)
The same as above but with different exit time.
• Hold-up zone
The zone is always enabled (even if the control panel is disarmed). It releases a silent alarm (neither acoustic nor
optical signaling) with maximum priority.
• Key zone
The zone permits arming/disarming of the program it is included in by mechanical key or push button connected
to it. The functioning mode of the key zone can be programmed as on/off or pulse (see also the option window).
• Tamper zone
The zone is direct and always enabled (even if the control panel is disarmed). It is equivalent to the ZT input and
releases zone tamper alarms.
Содержание TP8-96
Страница 4: ...IV Installer Manual TP8 96 VIDEO...
Страница 15: ...TP8 96 VIDEO Installer manual Introduction to the TP8 96 VIDEO system 1 9 OUTPUT EXTENSIONS MAX 16...
Страница 16: ...Introduction to the TP8 96 VIDEO system Installer manual TP8 96 VIDEO 1 10...
Страница 17: ...TP8 96 VIDEO Installer manual Introduction to the TP8 96 VIDEO system 1 11...
Страница 44: ...Zoneconfiguration Installer Manual TP8 96 VIDEO 2 26...
Страница 60: ...Telephonesectionconfiguration Installer Manual TP8 96 VIDEO 3 16...
Страница 66: ...Telephonesectionconfiguration Installer Manual TP8 96 VIDEO 3 22...
Страница 76: ...Timeparameterconfiguration Installer Manual TP8 96 VIDEO 4 10 Test call server Access periods...
Страница 88: ...Accessconfiguration Installer Manual TP8 96 VIDEO 5 12...
Страница 102: ...Special procedures Installer Manual TP8 96 VIDEO A 2...
Страница 111: ...TP8 96 VIDEO Installer Manual Special procedures A 11 ELECTRONIC BOARD...
Страница 113: ...TP8 96 VIDEO Installer Manual Special procedures A 13 SYSTEM...
Страница 114: ...Special procedures Installer Manual TP8 96 VIDEO A 14 CAMERA CONNECTION...
Страница 115: ...TP8 96 VIDEO Installer Manual Special procedures A 15 SUPPLY BY TERMINALS...
Страница 116: ...Special procedures Installer Manual TP8 96 VIDEO A 16 SUPPLY BY CABLES SPLITTER...
Страница 117: ...TP8 96 VIDEO Installer Manual Special procedures A 17...